Sign In
Upload
Manuals
Brands
Argo-Hytos Manuals
Measuring Instruments
OPCom
Argo-Hytos OPCom Manuals
Manuals and User Guides for Argo-Hytos OPCom. We have
2
Argo-Hytos OPCom manuals available for free PDF download: Operating Manual, Manual
Argo-Hytos OPCom Operating Manual (69 pages)
Particle Monitor
Brand:
Argo-Hytos
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
Contents
2
1 About this Documentation
5
Applicability of this Documentation
5
Required and Supplementary Documentation
5
Presentation of Information
5
Safety Instructions
5
Symbols
6
Terms
6
Abbreviations
6
2 Safety Instructions
7
About this Chapter
7
Intended Use
7
Improper Use
7
Reasonably Foreseeable Misuse
7
Qualification of Personnel
7
General Safety Instructions
8
Product and Technology Related Safety Instructions
8
Indications on the Product
8
3 General Instructions
10
4 Scope of Delivery
11
5 About this Product
12
Functional Description
12
Component Overview
13
Identification of the Product
13
6 Transport and Storage
14
7 Assembly
15
Operating Site
15
Hydraulic Connection
15
Mounting
16
Mechanical Stress
17
8 Electrical Connection
18
Pin Assignment (View from Above)
18
9 Commissioning
19
Before Commissioning
19
10 Start Screen
20
Status Display
20
Time Display
20
Displayed Standard
20
Ordinal Numbers
20
11 Menu and Operation
21
Menu Structure
22
Operating Modes
23
Time-Controlled Measurement
23
Digital I/O
23
Button
23
Automatic
24
Alarm Configuration
24
Alarm Type
24
Standard Alarm
24
Filter Mode
25
Temperature Alarm
25
Alarm Memory
25
Low-Pass Filter
25
Configuration Analog
26
Standard
27
Configuration Flow
27
Automatic
27
Fix
27
Communication
27
Type
27
Baud Rate CAN
28
Node ID CAN
28
Baud Rate RS232
28
Automatic Transmission
28
Configuration Display
29
Sensor Parameter
29
Measurement Results
29
Electronics
29
Operating Hours
30
Error Info
30
Flow Settings
30
Language
30
12 Calibration
31
Calibration Note
31
13 Analog Current Output (4
32
Measurement Without Load Resistance
32
Measurement with Load Resistance
32
Configuration
32
Conversion of the Analog Current Output to the Ordinal Number
32
Sequential Data Output for ISO 4406:17 and SAE as 4059E
33
14 Switching Inputs and Outputs
34
Digital Input
34
Switching Output
34
Option 1
34
Option 2
35
15 Communication RS232
36
Interface Parameters
36
Read Commands
36
Configuration Commands
38
Checksum Calculation (CRC)
41
16 Communication CAN
42
Canopen
42
Canopen Object Dictionary" in General
43
Canopen Communication Objects
43
Service Data Object (SDO)
44
Process Data Object (PDO)
46
PDO Mapping
46
Canopen Object Dictionary" in Detail
48
Can J1939
53
17 Classification Systems
54
Definition of Particle Sizes
54
Cleanliness Classes According to ISO 4406:17
54
Cleanliness Classes According to SAE as 4059E
55
Cleanliness Classes According to NAS 1638
56
Cleanliness Classes According to GOST 17216
57
18 Maintenance and Repair
58
Maintenance
58
Repair
58
19 Decommissioning, Disassembly, Disposal
59
Environment
59
20 Accessories
60
21 Troubleshooting
61
22 Faq
62
23 Technical Data
64
Dimensional Drawing
65
24 Appendix
66
Cable Lengths
66
Coding of Error Bits
66
Particle Contaminations
68
Advertisement
Argo-Hytos OPCom Manual (47 pages)
Portable Oil Lab
Brand:
Argo-Hytos
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Contents
2
Table of Contents
2
1 About this Documentation
4
Applicability of this Documentation
4
Required and Supplementary Documentation
4
Presentation of Information
4
Safety Instructions in this Documentation
4
Symbols
5
2 Safety Instructions
6
About this Chapter
6
Intended Use
6
Improper Use
6
Reasonably Foreseeable Misuse
6
Qualification of Personnel
6
General Safety Instructions
7
Product and Technology Related Safety Instructions
7
3 General Instructions
8
4 Scope of Delivery
9
5 About this Product
10
Functional Description
10
Measured Values
10
Component Overview
11
Controls
12
Control Panel
12
Printer
13
Identification of the Product
13
6 Transport and Storage
14
7 Assembly
15
Operating Site
15
Hydraulic Connection
15
Electrical Connection
17
Charging Process
18
8 Commissioning
19
Before Commissioning
19
9 Operation
20
Operation
20
Menu Structure
21
Switching on the Device
23
Start Screen
24
Measurement Quick Menu
25
Memory Quick Menu
25
Main Menu
26
Memory Menu
26
Measurement Settings
28
System Settings
31
Select Start Screen
31
Print Selection
33
Display
35
Time / Date
36
Language
36
10 Maintenance / Repair
37
Maintenance
37
Repair
37
Spare Parts
37
11 Software
38
12 Decomissioning
39
13 Disassembly
40
14 Disposal
41
Environmental Protection
41
15 Extension and Conversion
42
Accessories
42
16 Troubleshooting
43
Basic Procedures
43
17 Technical Data
44
Dimensional Drawing
45
18 Appendix
46
Declaration of Conformity
46
Advertisement
Related Products
Argo-Hytos OPCom II
Argo-Hytos OPS 010
Argo-Hytos Categories
Control Unit
Water Filtration Systems
Measuring Instruments
Water System
Controller
More Argo-Hytos Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL