Table of Contents
Table of Contents
2
1 Manual Revision Notes
7
Version 2 Revision Notes
7
Version 1 Revision Notes
7
2 Abbreviations
9
3 General
10
4 IED User Interface
11
Panel Structure
11
AQ 200 Series Local Panel Structure
11
MIMIC and Main Menu
12
Basic con Guration
12
Navigation in Main con Guration Menus
12
General Menu
13
Protection Menu
13
Control Menu
25
Communication Menu
35
Measurement Menu
37
Monitoring Menu
40
User Level Password con Guration
44
5 Functions
45
Functions Included in AQ-F210
45
Measurements
46
Current Measurement and Scaling
46
Frequency Tracking and Scaling
57
General Menu
60
Protection Functions
61
General Properties of a Protection Function
61
Non-Directional Overcurrent I> (50/51)
74
Non-Directional Earth Fault I0> (50N/51N)
79
Current Unbalance I2
83
Harmonic Overcurrent Ih> (50H/51H/68H)
88
Circuit Breaker Failure Protection CBFP (50BF)
92
Restricted Earth Fault / Cable End Differential (REF) I0D> (87N)
106
Line Thermal Overload Protection TF> (49F)
112
Arc Fault Protection Iarc>/I0Arc>(50Arc/50Narc)
130
Programmable Stage
136
Control Functions
149
Setting Group Selection (SGS)
149
Object Control and Monitoring (OBJ)
155
Indicator Object Monitoring (CIN)
160
Auto-Reclosing 0 → 1 (79)
161
Auto-Reclosing 0 → 1 (79)
162
Cold Load Pick-Up (CLPU)
185
Switch on to Fault (SOTF)
194
Ma Output Control
196
Programmable Control Switch
200
Monitoring Functions
200
Current Transformer Supervision (CTS)
200
Disturbance Recorder (DR)
209
Measurement Recorder
216
Circuit Breaker Wear-Monitor (CBW)
220
Total Harmonic Distortion Monitor (THD)
224
Measurement Value Recorder
228
6 System Integration
232
Communication Protocols
232
Ntp
232
Modbustcp and Modbusrtu
232
Modbusio
233
Version
233
Iec 61850
234
Goose
236
Iec
238
Dnp3
238
Iec 101/104
238
SPA Protocol
239
General IO Analog Fault Registers
239
Real Time Measurements to Communication
239
7 Applications and Connection Examples
242
Connections AQ-F210
242
Example Feeder Application Connection
244
3-Phase, 3-Wire ARON Input Connection
245
Trip Circuit Supervision (95)
246
8 Construction and Installation
250
CPU, IO and Power Supply Module
252
Current Measurement Module
254
Binary Input Module (DI8) (Option)
255
Binary Output Module (DO5) (Option)
257
Arc Protection Module (Option)
258
RTD & Ma Input Module (Option)
259
Serial RS232 Communication Module (Option)
260
LC100 Ethernet Communication Module (Option)
262
Maout & Mainput Module (Option)
263
Installation Dimensioning
263
9 Technical Data
266
Hardware
266
Measurements
266
Current Measurement
266
Frequency Measurement
267
CPU & Power Supply
267
Auxiliary Voltage
267
CPU Communication Ports
268
CPU Binary Inputs
269
CPU Binary Outputs
269
Option Cards
270
Binary Input Module
270
Binary Output Module
270
Arc Protection Module
271
Maout & Main Module
272
RTD & Ma Input Module
272
RS232 & Serial Ber Communication Module
272
Double Lc100Mb Ethernet Module (Redundant)
273
Display
273
Functions
273
Protection Functions
273
Non-Directional Overcurrent (50/51) I
273
Non-Directional Earth Fault (50N/51N) I0
274
Current Unbalance (46/46R/46L) I2
275
Harmonic Overcurrent (50H/51H, 68) Ih
276
Circuit Breaker Failure Protection (50BF/52BF) CBFP
277
Restricted Earth Fault / Cable End Differential (87N) Iod
277
Line Thermal Overload (49L) TF
278
Resistance Temperature Detector Alarm (49RTD) T
278
Arc Protection (50ARC/50NARC) IARC> I0ARC> (Option)
278
Control Functions
279
Setting Group Selection
279
Object Control (OBJ)
279
Autoreclosing Function (79) 0 → 1
280
Cold Load Pick-Up (CLP)
280
Switch on to Fault (SOTF)
281
Monitoring Functions
281
Current Transformer Supervision (CTS)
281
Disturbance Recorder (DR)
282
Circuit Breaker Wear Monitor (CBW)
282
Total Harmonic Distortion (THD)
282
Voltage Memory (Integrated in 67,21G)
283
Tests and Environmental
283
10 Ordering Information
286
11 Contact and Reference Information
288
Advertisement
Arcteq AQ-F210 Instruction Manual (292 pages)
Feeder Protection IED
Brand:
Arcteq
| Category:
Protection Device
| Size: 12 MB
Table of Contents
Table of Contents
3
1 Abbreviations
6
2 General
7
3 Ied User Interface
8
AQ 200 Series Local Panel Structure
8
IED Programming
8
Basic Configuration
8
Navigation in Main Configuration Menus
10
4 Functions of Aq-F210 Feeder Protection Ied
38
Measurements
39
Current Measurement and Scaling
39
Frequency Tracking and Sampling
51
Protection Functions
54
General Properties of a Protection Function
54
Non-Directional over Current I> (50/51)
67
Non-Directional Earth Fault I0> (50N/51N)
74
Current Unbalance I2> (46)
80
Harmonic over Current IH> (50H/51H/68H)
88
Circuit Breaker Failure Protection (CBFP) (50BF)
96
Restricted Earth Fault / Cable End Differential (REF) I0D> (87N)
109
Thermal Overload Protection for Feeders T > (49F)
117
Arc Protection Iarc>/I0Arc> (50Arc/50Narc)
136
Control Functions
143
Setting Group Selection (SGS)
143
Object Control and Monitoring (OBJ)
151
Auto-Reclosing 0 1 (79)
161
Cold Load Pick-Up (CLPU)
190
Switch on to Fault (SOTF)
198
Monitoring Functions
201
Current Transformer Supervision (CTS)
201
Disturbance Recorder (DR)
211
Measurement Recorder
221
Circuit Breaker Wear -Monitor (CBW)
222
Total Harmonic Distortion Monitor (THD)
228
5 System Integration
234
Communication Protocols
234
5.1.1 Ntp
234
Modbustcp and Modbusrtu
235
Modbusio
236
5.1.4 Iec 61850
236
5.1.5 Goose
240
Iec 103
241
5.1.7 Dnp3
242
Iec 101 / 104
242
SPA Protocol
243
6 Connections
244
7 Construction and Installation
247
CPU, IO and Power Supply Module
249
Current Measurement Module
250
Digital Input Module DI8
251
Digital Output Module DO5
252
Arc Protection Module (Option)
253
Rtd & M Ainput Module Option
254
Serial RS232 & Serial Fiber Module (Option)
256
Double LC 100 Mb Ethernet Module (Option)
257
Installation and Dimensions
257
8 Applications
260
3-Phase, 3-Wire ARON Input Connection Example
260
Trip Circuit Supervision
261
Trip Circuit Open Coil Supervision with One Digital Input and Connected Trip Output
261
Trip Circuit Open Coil Supervision with One Digital Input and Connected and Latched Trip Output
263
9 Technical Data
265
Connections
265
Measurements
265
Auxiliary Voltage
266
Binary Inputs
266
Binary Outputs
267
Arc Protection Card (Option)
268
Communication Ports
269
Protection Functions
270
Current Protection Functions
270
Arc Protection Function
277
Control Functions
278
Monitoring Functions
282
Tests and Environmental
288
Electrical Environment Compatibility
288
Physical Environment Compatibility
289
Casing and Package
289
10 Ordering Information
290
11 Reference Information
292
Advertisement
Related Products
Arcteq AQ F205
Arcteq AQ-F201
Arcteq AQ-F215
Arcteq AQ-F255
Arcteq AQ 1000
Arcteq AQ-T257
Arcteq AQ-S215
Arcteq AQ-F213
Arcteq AQ F3 0 Series
Arcteq AQ-103
Arcteq Categories
Protection Device
Relays
Accessories
Security Sensors
Industrial Electrical
More Arcteq Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL