Sign In
Upload
Manuals
Brands
Ametek Manuals
Industrial Equipment
VersaSCAN
Ametek VersaSCAN Manuals
Manuals and User Guides for Ametek VersaSCAN. We have
1
Ametek VersaSCAN manual available for free PDF download: System Manual
Ametek VersaSCAN System Manual (156 pages)
Electrochemical Scanning Base
Brand:
Ametek
| Category:
Industrial Equipment
| Size: 7 MB
Table of Contents
Table of Contents
2
Figures
5
Versascan Base (VSC-BASE)
11
VSC-BASE Packing List
11
Table 1. VSC-BASE Packing List
11
Versascan Initial Assembly and Set-Up
12
Figure 1. Mount Stage Assembly
12
Figure 2. Bubble Level
12
Axis Lockers
13
Figure 3. Mounting Interface Block to Assembly
13
Connectivity and Setting the IP Addresses
14
Figure 4. Axis Lockers
14
Table 2. Default IP Addresses
14
Getting Started and Home Routine
15
Figure 5. Versascan Warning Message
15
Manual Control
16
Figure 6. Home Screen
16
Probe Position and Experiment Status
17
Figure 7. Status Bar
17
Versascan SECM (VSC-SECM)
19
SECM Technique Overview and Introduction
19
Figure 8. Approach Curve
19
Applications
20
Figure 9. Example of Generator-Collector Mode
20
VSC-SECM Packing List
21
Cable Connections for VSC-SECM
21
Figure 10. SECM Set-Up Diagram
21
Table 3. VSC-SECM Packing List
21
Figure 11. Connection Diagram for VSC-SECM
22
Table 4. Cell Connections for SECM
22
Figure 12. Hardware Requirements Screen
23
Table 5. Potentiostat Connections for VSC-SECM in Feedback Mode
23
Table 6. Potentiostat Connections for VSC-SECM in Generator-Collector Mode
23
Software Control for VSC-SECM
24
Comments
24
Conditioning
24
Scan Setup
24
Figure 13. Comments Field
24
Figure 14. Conditioning
24
Scan Type
25
Measurement Mode
25
Figure 15. Scan Setup Screen
25
Start X / y / Z
26
End Vs. Start
26
Step Size
26
Figure 16. Area Scan Example
26
Measurement Mode Setup
27
Line Delay
27
Measure Delay
27
Measure Probe and Measure Sample
27
Figure 17. Measurement Mode Setup
27
VSC-SECM System Test Procedure for Gold Disk Test Sample
29
Materials
29
Setup
29
Figure 18. Versastudio Icon
30
Figure 19. Experiment Properties
31
Figure 20. Experiment Results
31
Figure 21. CV of 5Mm Gold Sample
32
Running Approach Curves
33
Figure 22. Current Versus Position for Insulator
34
Figure 23. Current Versus Position for Conductor
35
Line Scans and Area Maps
36
Figure 24. Insulator Versus Conductor Comparison
36
Figure 25. Area Maps
37
Ac-Secm
39
Introduction
39
Figure 26. AC-SECM Setup
39
Figure 27. Limiting Case Number 1
40
Figure 28. Limiting Case Number 2
40
Table 7. Limiting Case Number 1 Circuit Element Definitions
40
Figure 29. High Frequency And/Or Low Electrolyte Concentration Current Flow
41
Table 8. Limiting Case Number 2 Circuit Element Definitions
41
Figure 30. High Frequency And/Or Low Electrolyte Concentration Graph
42
Example Data
43
Figure 31. Low Frequency And/Or High Electrolyte Concentration Current Flow
43
Figure 32. Low Frequency And/Or High Electrolyte Concentration Graph
43
Approach Curves
44
Figure 33. Scan Setup
44
Feedback Mode X-Y Scan
45
Figure 34. AC-SECM Approach Curve Response for an Insulator
45
Figure 35. AC-SECM Approach Curve Response for a Conductor
45
Figure 36. Typical Set of AC-SECM Results Across Insulator/Gold Sample
46
VSC-Soft Stylus Probe SECM
47
Technique Overview and Introduction
47
Theory of Operation
47
Figure 37. Cross Section of Carbon Probe after Cutting the Probe
47
Figure 38. Examples of Probe Contact
48
Probe Preparation and Handling
49
Figure 39. Probe Positioning
49
Probe Preparation
50
Figure 40. Probe Handing Example
50
Figure 41. Probe Cutting Diagram
51
Figure 42. Probe Cutting Lines
52
Figure 43. Final Probe
52
Figure 44. Razor Tool Supplied with the System
53
Figure 45. Probe Cutting Demonstration
53
Figure 46. Probe Cutting Direction
54
Figure 47. Probe Holder Pieces
54
Figure 48. Delamination of Parylene C Coating
55
Figure 49. Electrode Loaded into Top Holder
56
Figure 50. Copper Pad Place on the Probe
56
Figure 51. Place Gold-Plated Connector
57
Figure 52. Connector in Position
57
Figure 53. Holder Screwed Onto Plate
58
Figure 54. Probe Mounted on Base Plate and Positioner Stage
58
Electrochemistry of the Probes
59
Using the Positioning Scales
59
Figure 55. Cyclic Voltammogram of Fcmeoh in 0.1M KNO
59
Figure 56. Rotary Optical Positioning Scales
60
Figure 57. Example of Probe Angle
60
Positioning the Probe
61
Figure 58. Probe Scanning Demo
61
Running Constant Distance Mode SECM Experiments
62
Figure 59. Correct Probe Bend Versus Incorrect Probe Bend
62
Figure 60. Select Soft Stylus Probe SECM
62
Learning to Position the Probe Manually
63
Figure 61. Manual Control Button
63
Figure 62. Current Versus Height
63
Positioning Probe for Line and Area Scans
64
Example Area Scan Setup
64
Figure 63. Scan Setup
64
Versascan LEIS (VSC-LEIS)
65
LEIS Technique Overview and Introduction
65
Applications
65
Figure 64. LEIS Dummy Cell Response - Frequency Sweep
66
Figure 65. Results from Gold Point-In-Space in Tap Water with 100Mv Applied
66
VSC-LEIS Packing List
67
Cable Connections for VSC-LEIS
67
Figure 66. LEIS Setup Diagram
67
Table 9. VSC-LEIS Packing List
67
Figure 67. LEIS Connections
68
Table 10. Cell Connections for LEIS
68
Software Control for VSC-LEIS
69
Comments
69
Conditioning
69
Scan Setup
69
Figure 68. Software Comments Field
69
Figure 69. Software Conditioning Field
69
Figure 70. Software Scan Setup
70
Figure 71. Area Scan
71
Measurement & Delay
72
Potentiostat Setup
72
Figure 72. Software Measurement and Delay
72
Figure 73. Software Potentiostat Setup
72
Impedance Setup
73
Figure 74. Software Impedance Setup
73
VSC-LEIS System Test Procedure for LEIS Dummy Cell
74
Figure 75. Manual Control Settings
75
Figure 76. Versascan Dummy Cell
75
Table 11. LEIS Cable Connections for LEIS Dummy Cell
75
Figure 77. Surface Imaging and Scanning
76
Figure 78. Scan Setup - Select Point
76
Figure 79. Run Icon
77
VSC-LEIS System Test Procedure for Gold Wire Test Sample
78
Figure 80. LEIS Dummy Cell Test Results
78
Figure 81. LEIS Setup for Gold Wire Test Sample
79
Figure 82. V3 Connections
79
Table 12. LEIS Cable Connections for Gold Wire Test Sample
79
Figure 83. LEIS Probe Mounting in the PT Wire Counter Electrode
80
Figure 84. Manual Control Settings
80
Figure 85. Surface Imaging and Scanning
81
Figure 86. Scan Setup
81
Figure 87. Run Experiment Icon
82
Figure 88. Gold Wire Test Sample Results
83
Figure 89. Probe Scan Results
84
Versascan SVET (VSC-SVET)
85
SVET Technique Overview and Introduction
85
Applications
85
Figure 90. Results from Gold Point-In-Space in Tap Water with -10Ua Applied
85
VSC-SVET Packing List
86
Figure 91. Results from Bare Metal Corrosion Process
86
Table 13. VSC-SVET Packing List
86
Cable Connections for VSC-SVET
87
Figure 92. SVET Setup Diagram
87
Figure 93. SVET Open Circuit Cable Connections
87
Software Control for VSC-SVET
88
Comments
88
Figure 95. Software Comments Field
88
Conditioning
89
Scan Setup
89
Figure 96. Software Conditioning Field
89
Figure 97. Scan Setup
89
Signal Conditioning
91
Figure 98. Area Scan
91
Figure 99. Software Signal Conditioning
91
The Lock-In Amplifier
92
Figure 100.VSC-SVET Signal Conditioning Diagram
92
Figure 101. Electrometer Gain Diagram
92
Figure 102. SVET Reference Wave Signal
93
Figure 103. Reference Wave Diagram
94
Figure 104. Software Reference Phase Settings
94
VSC-SVET System Test Procedure for Gold Wire Test Sample
95
Figure 105. Measurement and Delay Settings
95
Figure 106. VSC SVET Setup for Gold Wire Test Sample
96
Figure 107. Manual Control Settings
96
Figure 108. Surface Imaging and Scanning
97
Figure 109. SVET Scan Setup
98
Figure 110. Scanning Area Diagram
98
Figure 111. SVET Signal Conditioning
99
Figure 112. Run Icon
99
Figure 113. SVET Test Results
100
Versascan SKP (VSC-SKP)
101
SVET Technique Overview and Introduction
101
Key Points of SKP
102
Figure 114. Energy Levels at Different Stages of the SKP Experiment
102
Figure 115. Zinc/Galvanized Steel Response Using VSC-SKP
102
VSC-SKP Packing List
103
Cable Connections for VSC-SKP
103
Figure 116. SKP Setup Diagram
103
Table 14. VSC-SKP Packing List
103
Figure 117. SKP Cable Connections
104
Table 15. Cell Connections for SKP
104
Software Control for VSC-SKP
105
Comments
105
Conditioning
105
Scan Setup
105
Figure 118. Software Comment Field
105
Figure 119. Conditioning Tab
105
Figure 120. Software Scan Setup
106
Signal Conditioning
107
Figure 121. Area Scan
107
Backing Potential Controller
108
Figure 122. Signal Conditioning
108
Figure 123. Backing Potential Controller
108
Electrometer Gain
109
The Lock-In Amplifier
109
Lock-In Input
109
Figure 124. VSC-SKP Signal Conditioning Diagram
109
Figure 125. Electrometer Gain Diagram
109
Time Constant
110
Reference Wave
110
Figure 126. SKP Reference Wave Signal
110
Figure 127. Reference Wave Diagram
110
Measurement & Delay
111
Figure 128. Software Reference Phase Settings
111
Figure 129. Measurement and Delay
111
VSC-SKP System Test Procedure for Zinc/Steel Sample
112
Figure 130. the SKP Test Sample
112
Figure 131. VSC-LCELL
113
Figure 132. SKP Test Sample Mounted to Cell
113
Table 16. SKP Cable Connections
113
Figure 133. Manual Control Settings
114
Figure 134. 500Um SKP Probe @ 100 Microns from the Sample
114
Figure 135. Surface Imaging and Scanning
115
Figure 136. SKP Scan Setup
116
Figure 137. SKP Scan Area
116
Figure 138. SKP Signal Conditioning
117
Figure 139. Backing Potential Controller
117
Figure 140. Run Icon
118
Figure 141. SKP Test Results
118
Versascan SDC (VSC-SDC)
119
SDC Technique Overview and Introduction
119
Applications
119
Figure 142. Results from Gold Disk in 3M Kcl with -500 MV
119
VSC-SDC Packing List
120
Figure 143. Schematic of the SDC Head with Reference and Counter Electrodes
120
Table 17. VSC-SDC Packing List
120
Cable Connections for VSC-SDC
121
Preparing the VSC-SDC Head for Use
121
Figure 144. SDC Setup Diagram
121
Figure 145. SDC Cable Connections
121
Figure 146. Parts Required for Preliminary/Sdc Head Assembly
122
Figure 147. Placing the PTFE Tape
122
Figure 148. Fittings with PTFE Tape
123
Figure 149. SDC Head with Its Fittings Properly Installed
123
Figure 150. Cord Grip with Caps Removed
124
Pump Setup
125
Figure 151. Looking into Counter Electrode Opening on SDC Head
125
Figure 152. Positioning Electrodes in SDC Head
125
Figure 153. Steps for Releasing Cassette Button
126
Figure 154. Peristaltic Pump Cassette with PVC Tubing Set Properly Installed
126
Figure 155. Steps for Reinserting Pump Cassette
127
Figure 156. Tubing Connected to SDC Head
127
Figure 157. General Schematic of Liquid Flow through the SDC System
128
Figure 158. Semi-Transparent View of SDC Head and Solution Flow Path
129
Figure 159. Closeup of SDC Head's Tip
129
SDC Flow Balancing
130
The Connections
130
The Sample
131
The Pump
131
The SDC Reference Electrode
132
SDC Head Positioning
132
Figure 160. Proper Positioning of Reference Electrode in SDC Head
132
Tube Clamps
133
Figure 161. Proper Clamp Location
133
SDC Pump Calibration
134
Figure 162. General Flow Schematic for SDC System
134
Figure 163. Peristaltic Pump Interface
135
Figure 164. Flow Calibration Example
135
Reference Electrode
136
Figure 165. Removing the Reference Electrode Sheath
136
VSC-SDC System Test Procedure for Gold Disk Test Sample
137
Figure 166. Inspection of Frit
137
Figure 167. SDC (and SECM) Standard Test Sample
138
Figure 168. Versacam Camera Showing the Head Being Brought Towards the Sample
138
Figure 169. Versascan's Software Manual Control for Stage Movement
139
Figure 170. SDC Head in Close Proximity to the Sample Forming a Liquid "Microcell
139
Figure 171. SDC Test Showing SDC Results over the Whole 5Mm au SDC Test Sample
140
Versascan Optical Surface Profiling (VSC-OSP)
141
OSP Technique Overview and Introduction
141
Applications
141
VSC-OSP Packing List
142
Cable Connections for VSC-OSP
142
Figure 172. OSP Setup Diagram
142
Table 18. VSC-OSP Packing List
142
Software Control for VSC-OSP
143
Comments
143
Figure 173. OSP Cable Connections
143
Figure 174. Comment Field
143
Conditioning
144
Scan Setup
144
Figure 175. Conditioning Tab
144
Figure 176. Scan Setup
144
Measurement Mode Setup
146
Optical Sensor Setup
146
Figure 177. Area Scan
146
Figure 178. Measurement and Delay
146
Figure 179. Optical Sensor Setup
146
VSC-OSP System Test Procedure for Slip Gauge Samples
147
Versascan Mlcell (VSC-MLCELL)
149
Figure 180. VSC-MLCELL Parts Diagram
149
Table 19. VSC-MLCELL Parts List
150
Versascan LCELL (VSC-LCELL)
151
Figure 181. VSC-LCELL Parts Diagram
151
Figure 182. Complete VSC-LCELL
152
Table 20. VSC-LCELL Parts List
152
Appendix 1. System Connections for Two Stage Motion Controller
153
Figure 183. Connection Diagram for VSC-SECM
153
Table 21. Cable Connections for VSC-SECM with System Control Box, Using Bypass
153
Cable
153
Figure 184. LEIS Cable Connections
154
Figure 185. V3F
154
Table 22. Cable Connections for VSC-SECM Without System Control Box
154
Figure 186. SVET Cable Connections for Open Circuit Controlled Sample
155
Figure 187. SVET Cable Connections for Galvanostatic/Potentiostatic Controlled
155
Figure 188. SKP Cable Connections
156
Figure 189. SDC Cable Connections
156
Advertisement
Advertisement
Related Products
Ametek VersaSTAT MC
Ametek VersaSTAT LC Series
Ametek VersaSTAT 4
Ametek VDS 200Q Series
Ametek VDS 200Q25.2
Ametek VDS 200Q50.2
Ametek VDS 200Q100.2
Ametek VDS 200Q150.2
Ametek VDS 200Q200.2
Ametek VSS 500N
Ametek Categories
Measuring Instruments
Test Equipment
Power Supply
Switch
Controller
More Ametek Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL