Sign In
Upload
Manuals
Brands
ABX Manuals
Measuring Instruments
Pentra 80 RAB108DB
ABX Pentra 80 RAB108DB Manuals
Manuals and User Guides for ABX Pentra 80 RAB108DB. We have
1
ABX Pentra 80 RAB108DB manual available for free PDF download: User Manual
ABX Pentra 80 RAB108DB User Manual (306 pages)
Brand:
ABX
| Category:
Measuring Instruments
| Size: 19 MB
Table of Contents
Introduction
13
Table of Contents
13
1 Warning and Precautions
14
Limited Guarantee
14
Safety Precautions
15
Graphics and Symbols
16
2 Labels
17
Input/Output Labels
17
PC Connections Label
19
3 Operational Conditions
20
Environment
20
Location
20
Grounding
21
Humidity/Temperature Conditions
21
Electromagnetic Environment Check
21
Environmental Protection
21
Transportation and Storage Conditions
22
Installation
22
Interconnections
23
Racks
24
4 Software Overview
25
Generic Toolbar Description
26
Contextual Toolbar Description
27
Main Menu Description
28
Miscellaneous
29
5 Workflow Overview
33
Order Overview
33
Worklist Overview
35
Runs and Results Overview
36
Archives Overview
37
Results Production
39
6 Printer
40
Daily Guide
41
1 Instrument Startup
42
Waste Levels
42
Printer Start up
42
Pentra 80 Startup
42
Automatic Startup
43
Manual Startup
43
Background Count Verification
43
Status
45
2 Running the ABX Quality Control
46
Closed Tube Mode with Barcode
46
Open Tube
47
3 Running Specimen
49
Sample Identification with Internal Barcode Reader
49
Non-Identified Sample with External Barcode Reader
49
Stat Mode
51
Run in Progress
52
4 Results
53
Printing a Result Series
53
Unmatched Results
54
5 Archives
55
Searching Results by Day
55
Searching Results by Patient
55
6 Instrument Shutdown
56
Manual Shutdown
56
Quality Assurance
57
1 Quality Control
59
Access to the Quality Control Menu
60
Graphs
62
L.J. Graphs
62
QC Data Screen Grid
63
Graphics Screen
64
Print, Send or Delete Results
65
Printing Results
65
Sending Results to the LIS
65
Deleting Results
66
New Blood Control Setup
66
Running Control Blood
69
Running in STAT Mode
69
Running in Rack Mode (with Barcode Label Identification)
69
2 Patient Quality Control (XB)
70
Access to the XB Menu
71
XB Graphs
72
XB Data Grid Screen
73
Batch Content
74
XB Limits
75
3 Within Run
76
Accessing the Within Run Data Grid
76
Closed Tube Sample Setting
78
Running Cycles
78
Manual Mode
78
Rack Mode
78
Results
79
Print/Transmit or Delete Results
79
4 Calibration
81
Accessing the Calibration Main Menu
81
Target Values
82
Running Calibration
83
Calibration Passed
84
Forced» Calibration
85
Coefficients of Calibration Ranges
85
Printing, Sending or Deleting Calibration Results3-30
86
5 Logs
88
Access to «Logs» Function
88
Calibration Logs
90
Quality Control Logs
90
Reagent Logs
91
Settings Logs
91
Maintenance Logs
91
Patient Logs
92
Workflow
93
1 Workflow
95
Sample Tube Management
95
Worklist
96
Workflow
96
Sample Identification
97
Barcode Identification
97
Setting: Barcode / Manual Match = off
98
Setting: Barcode / Manual Match = on
99
Sample Identification on Rack/Position
100
Setting: Rack/Position / Manual Match = off
100
Setting: Rack/Position / Manual Match = on
101
Exception Management
103
Sample Identification on both Barcode and Rack/Position
104
Identification with Barcode, Without Order
104
Sample Tube and Order Association
105
Patient File Management
105
Loading Worklist from the LIS
105
2 Worklist
106
Overview
106
Accessing the Worklist Function
106
Worklist Grid
107
Creating an Order
108
Contextual Toolbar Keys
108
Grid Functions
108
Order Information Fields
109
Searching by Sample ID
110
Searching by Patient Name
110
Printing out the Worklist
111
Rack View
112
Auto-Numbering
114
Rack View Contextual Toolbar Keys
114
Rack View Functions
114
Printing the Rack View
115
3 Sample Collection & Mixing
116
Recommended Anticoagulant
116
Blood Sample Stability
116
Microsampling
116
Mixing
116
4 Running Specimens
117
5 Run Results and Associated Flags
118
Printer Output Format
118
Flags
118
Result Screen
119
Normal and Panic Ranges
121
Flags
121
Results Exceeding Linear Ranges of the Instrument4-30
122
Analysis Reject
123
LMNE Matrix Flags
124
Flags on WBC/BAS Histogram
130
Flags on RBC Histogram
131
Flags on PLT Histograms
131
WBC Balance
133
Analyzer Alarms
134
Pathology Messages
135
Statistical Function Flags
138
6 Order & Sample Run Association
139
Reviewing Sample Results
139
Accessing the Result List
139
Result List Function Keys
139
Result Grid Information
140
Sorting out
141
Result Filters
141
Result Display
142
Result Display Keys
142
Rerunning Sample Manually
143
Printout or Transmit Result List
143
Result /Order Association
145
Association Grid Description
145
Association Grid Keys
146
Results/Orders Matching
146
7 Results Archives
147
Accessing the Results Archives
147
Daily Result Description
148
Patient Result
150
Patient Result Function Keys
151
Search Patient
151
Reviewing a Result in Full Screen Mode
152
Patient Result Screen
152
Daily Result Screen
152
Settings
153
1 Menu «Settings» Overview
155
Accessing the «Settings» Menu
155
Menu Settings Functions
156
2 Soft Parameters
157
Accessing the Soft Parameters Menu
157
General Tab
158
General Tab Functionalities
158
Automatic Numbering
158
RUO Parameters
158
Instrument Logs
159
Identification Option
159
Department/Physicians Tab
160
Units Tab
161
3 Quality Assurance Settings
163
Accessing the QA Settings
163
XB Options
163
Number of Calibration Runs
164
Coefficients of Variation Ranges
164
4 Rules
165
Accessing the «Rules» Screen
165
Rerun Conditions
165
Rerun on Alarms
166
Rerun by Parameters
166
Print Conditions
167
Transmit Conditions
168
5 System
169
Accessing the «System» Screen
169
Local Settings
169
Date and Time Format
169
Languages Options
170
Change Date and Time
170
Communication
171
RS232 Settings Tab
172
ABX/ASTM Format Tab
172
Printer
173
Printout Example
175
Printer Properties
176
Cycle Option
177
6 Save and Restore
178
Access to «Save/Restore» Screen
178
Configuration
178
Analyzer Setting Functions
178
Workstation Setting Functions
179
Dump Database
179
Update of the Help on Line of P80 Software
180
7 User Profiles
182
Accessing the User Screen
182
User Menu Function Keys
183
Creating a New «User» Profile
183
8 Sample Types
185
Accessing the «Types» Parameters Menu
185
Functions Keys
186
Creating a New Blood Sample Type
186
Modifying Limit/Alarm Values
186
Sample Type Copying
187
Type Automatic Association
187
Pathological Limits
188
Alarms & Curve Thresholds
189
Alarm Levels
189
5DIFF Matrix Thresholds
190
BAS Curve Threshold
191
Age Range
193
Description & Technology
195
1 Pentra 80 Description
196
Front View
196
Left Side View
196
Right Side View
197
Stat Tube Holder
197
Rear View
198
2 Automatic Mode Principles
199
3 Measuring Principles
203
Multi Distribution Sampling Sytem (MDSS)
203
CBC Mode
203
Diff Mode
203
Sample Distribution
204
CBC Detection Principles
205
Rbc/Plt
205
HGB Measurement
206
HCT Measurement
207
RDW Calculation
207
MCV, MCH, MCHC Calculation
207
MPV Measurement
207
Pct Calculation
207
PDW Calculation
208
WBC and Differential Count
209
General Counting Principles
209
BAS/WBC Count
209
LMNE Matrix Count
210
Maintenance & Troubleshooting
215
1 Maintenance & Troubleshooting Procedures
217
Hydraulic Cycles Maintenance Chart Table
217
Maintenance Procedures
217
Instrument General Cleaning
218
Instrument External Cleaning
218
Instrument Internal Cleaning
218
2 Replacement Procedures
219
Reagent Replacement
219
Reagent Locations and Connections
219
Integrated Reagents & Diluent Container Replacement7-6
220
Waste Container Replacement
225
Optical Bench Lamp Replacement
225
Lamp Replacement
225
Lamp Test
227
Sampling Probe Replacement
227
Rinse Chamber Filter Cleaning
229
Instrument Rinse
230
Syringes and Carriage Park
231
3 Instrument Panels & Cover Removals
232
Left Front Door Removal
232
Right Front Door Removal
233
Right-Hand Side Panel Removal
233
Left-Hand Side Panel Removal
234
4 Service Menu Description
235
5 Super User Menu Description
236
Mechanical Menu
237
Instrument Initialization
237
Check Motors
237
Check Valves
238
Check Sensors
239
Sampler Test
240
Sample Tube Holder Adjustment
241
Rack Adjustment
242
Hydraulical Menu
244
Drain Chambers
244
Prime Cycles
244
Unprime Cycle
246
Clean Cycles
247
Others
249
6 Troubleshooting
249
Troubleshooting
250
Instrument Operation Mode
251
Results
252
Flags
254
7 Hydraulic Diagram
256
8 Error Messages
257
Analyzer Error Types and Help Messages
258
Transfer Error Types and Help Messages
259
STAT Mode Error Type and Help Message
260
Environment Error Types and Help Messages
260
User Error Types and Help Messages
262
Expiration Date Error Types and Help Messages
262
Analyzer Internal Error Types and Help Messages
262
Specifications
265
1 Technical Specifications
266
Parameters
266
Throughput Analyses
267
Tube Identification
268
Reagents
268
Internal Computer
268
Measurements and Computation
268
2 Physical Specifications
269
Power Requirements
269
Operating Temperature and Humidity
269
Dimension and Weight
269
Minimum Specimen Volume
269
Dilution Ratios
269
HGB Measurement
269
Counting Aperture Diameters
269
Reagent Consumption (Ml)
270
Recommended Anticoagulant
270
3 Summary of Performance Data
271
Precision (Reproducibility)
271
Precision (Repeatability)
272
Linearity
273
Carryover
274
Normal Ranges
275
Accuracy
275
Leukocyte Differential Count
276
Sample Stability Study
276
Waste Handling Precautions
277
4 Limitations
278
Maintenance
278
Blood Specimens
278
Known Interfering Substances
278
5 Reagent Specifications
282
Advertisement
Advertisement
Related Products
ABX Pentra 80 RAB108EA
ABX Pentra 80 RAB108CA
ABX Pentra 80 RAB108DA
ABX Pentra 80 RAB108BA
ABX Categories
Radio
Measuring Instruments
Control Systems
More ABX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL