Checking flow
5
Damper checking method.
Inputting TEST Mode,
Check the damper and PCB.
(3)
(2)
6
Check the Fan motor.
Rotate fan using your hand.
Stuck change the motor.
(Cause of ice or rust inside of motor)
7
Check the R Fan motor voltage.
(1)
(2)(3)
(1)
(4)
<CON4>
- 40 -
Result & SVC Action
Test
Damper
Mode
State
1 Mode
Open
Damper is normal.
2 Mode
Closed
1,2
Not
Change the damper
mode
working
Point
Result
270 ~330
(1) to (2)
Other
270 ~330
(3) to (4)
Other
Point
Result
Sticky
Motor
Not Sticky
Point
Result
(1) ~ (2)
Below 12 V
(2) ~ (3)
0 or 5 V
SVC Action
(Go to 6)
SVC Action
It's normal
Change damper
It's normal
Change damper
SVC Action
Change the motor
Go to 7
SVC Action
Change the PCB
Change the motor