Designer Series Direct Vent Gas Fireplace
STLDV FRAMING
Remove box and
Insulation for Top
Vent Configurations
Figure 7 -
PFDV (Peninsula) Framing
The fireplace must be secured to the floor and/or to framing
studs as shown in Figure 7 . Use four (4) wood screws or
masonry/ concrete screws to secure fireplace to the floor.
Use four (4) screws to attach fireplace to framing. The side
brackets or nailing flanges are designed to accommodate
two wall boards thicknesses, 1/2" or 5/8".
10
46¹⁄₈" (1172 mm)
(1/2" Drywall)
or
46" (1168 mm)
(5/8" Drywall)
FP2850
Peninsula framing
INSTALLATION INFORMATION
23" (584 mm)
(1/2" Drywall)
or Adjustable to
22³⁄₄" (578 mm)
(5/8" Drywall)
NOTE: The Vermont Castings Group Model BPWC500
mantel is specially designed to comply with all mantel
temperature requirements. Any custom-built mantels must
comply with the framing clearances and the use of non-
combustibles as shown in Figures 5, 6 and 7.
The area above and on the sides of the
fireplace must be a noncombustible material.
Figures 5, 6, 7
Never install combustible materials over
front face of fireplace.
Noncombustible
Material
48³⁄₁₆"
(1224 mm)
If using 5/8" drywall, remove
framing tabs and re-install
on 2nd set of holes
positioned slightly inwards
Fold Outer Tabs
and Nail to Framing
Members
If using 5/8" drywall, remove
noncombustible supports,
rotate 180° and reinstall to
achieve 5/8" depth
20306750