8 Servicing
Connection of 2 Pipes with Hose
The correct connection of fuel lines with hoses is shown in
Fig. 805.
correct
hose clamp
wrong
bubble
Fig. 805 Pipe/Hose Connection
8.6.3 Dosing Pump
The dosing pump is a combined delivery, dosing and
shut-off system and is subject to certain installation
criteria (Fig. 801 and 806).
12 Volt and 24 Volt
Installation position horizontal only
Fig. 806 Dosing Pump, Installation Position
804
bubble
0 - 90°
0 - 90°
8.6.3.1 Installation Position
It is advantageous to mount the dosing pump in a cool
location. The ambient temperature must never exceed
+20° C during operation.
Dosing pump and fuel lines must not be installed in
locations exposed to heat radiated by hot vehicle
components (e.g. exhaust line). A heat shield is to be
provided as necessary.
8.6.3.2 Installation and Attachment
The dosing pump is to be attached with an anti-vibration
mount. The installation location is limited according to
Fig. 806 to ensure sufficient self-venting capability. Due to
the danger of corrosion only Webasto original parts may
be used for the plug connection between dosing pump
and dosing pump wiring harness.
8.6.4
Fuel Filter
If fuel contaminations are expected, only Webasto filter
order no. 487 171 may be used. The filter installation
should be vertical and never exceed horizontal (observe
direction of flow).
A
ø 5
Fig. 807 Fuel Filter
Air Top 3500/5000