Window Installation
StormPlust and Structural Installations
These instructions are applicable for the following Structural installations:
Clad Ultimate Double Hung Magnum
These instructions are applicable for the following StormPlus products:
1
Clad Casemaster
Clad Ultimate Double Hung (CUDH)
Clad Direct Glaze Polygon/Round Top
Clad Ultimate Double Hung Magnum
NOTE: Certified IZ2 and IZ3 Casemaster, Ultimate Double Hung, and Direct Glaze Polygon/Round Top
units must be installed using jamb screws or structural brackets. Certified IZ3 Ultimate Double Hung
Magnum units must be installed using the jamb screw method only.
ABSTRACT
These instructions advise the window installer/carpenter/contractor on the recommended way to install Marvin
windows where structural installation is necessary, including those rated for use in Impact Zones 2 and 3. Exact
installation methods for Impact Zone 4 windows are NOT included. Instead, refer to the Notice of Acceptance (see
details inside).
In addition to steps for installing your window, included within are: Rough opening (RO) preparation for recessed
masonry applications; RO prep and sealing details for standard wood frame construction; detailed fastening
methods and more.
The procedures within these instructions are consistent with those used in testing to achieve the advertised DP
rating. Contact your local Marvin dealer if your construction scenario differs from those detailed within.
Regional standard practices, environmental conditions and codes may vary and supersede the
procedures contained within. The responsibility for compliance is yours: the installer, inspector, and
owner(s). See the Technical Installation Specifications inside for more details.
1
Includes Awning, Operator, Picture 1", Stationary 3/4", Round Top Operator, and Round Top Stationary.
2
Includes Picture, Transom, Round Tops and Polygon
19970019
2012−04−10
2
Wood Ultimate Double Hung Magnum
1
Wood Casemaster
Wood Ultimate Double Hung (WUDH)
Wood Direct Glaze Polygon/Round Top
Wood Ultimate Double Hung Magnum
2

Advertisement

Table of Contents
loading

Summary of Contents for Marvin Window

  • Page 1 Impact Zone 4 windows are NOT included. Instead, refer to the Notice of Acceptance (see details inside). In addition to steps for installing your window, included within are: Rough opening (RO) preparation for recessed masonry applications; RO prep and sealing details for standard wood frame construction; detailed fastening methods and more.
  • Page 2: Table Of Contents

    Step Four − Final Installation Procedures Standard Frame Construction and Recessed Masonry Applications. Continuous Air Barrier Systems Installation, Integration, and window installation tips for house wrap. Removing Interior Stops, Liners, and Fillers Removing Casemaster interior stops, Removing Ultimate Double Hung jamb carriers Removing Sash .
  • Page 3: Technical Installation Specifications

    S Fasteners penetrating chemically treated lumber must be contact with a minimum of 0.90 oz/ft stainless steel type 304 or 316. S Clad window frames must not come into direct contact with chemically treated wood products. protection. zinc hot dipped galvanized or Window Installation...
  • Page 4: Before You Begin

    Sealant must be Grade NS Class 25 per ASTM C920 and compatible with building exterior and window surface. Optional, use low expansion foam insulation only. Foam and foam application must comply with ASTM E2112, section 5.9.2.
  • Page 5: Step One − Rough Opening And Framing Requirements

    (wood buck). You must fasten the buck to the masonry opening in a fashion that will withstand conditions which would be encountered under the certified and advertised DP ratings for this window. The structural integrity of this installation is only as good as the bond between the wood buck and the masonry opening.
  • Page 6 (13) NOTE: On standard wood frame construction with brick veneer, make sure there is at least 1/2, between bottom of window sill (or eventual placement of the window) and the top row of brick to avoid “brick bind”. 1/4″ (13)
  • Page 7: Step Two − Unit Preparation

    See figure 5. Tool the bead to ensure proper adhe- sion to both surfaces. 5. If you are installing a window with structural brackets, fasten to the window now. Follow the fastener spacing in the “Jamb/Sill Screw Chart”.
  • Page 8: Step Three − Installing The Window

    The following steps provide details for structural fastening of the window to the opening. When installing windows with nailing fin or wood brick mould casing, it may be desirable to first attach the window using these fastening methods in conjunction with steps 1−5. Then complete the installation by fastening with structural brackets or screws.
  • Page 9: Fastening Methods And Jamb/Sill Screw Chart

    UDHM IZ3 units must be installed with jamb screws, fastening at the sill is not required. Structural Brackets 1. Wrap brackets around the framing/buck/opening, fasten with two #8 x 1 5/8″ screws. Angle the screws approximately 15 degrees away from the window. Always shim above or behind installation brackets. Shim 1/4″...
  • Page 10 “Storm Brackets” on the jambs with two #8 x 2 1/2″ wood screws through the top bracket (64) and one screw through the bottom bracket. See the “Special Fastening Systems” section for more de- tails. Window Installation StormPlus and Structural Installations...
  • Page 11: Special Fastening Systems

    If the homeowner will be away from home for any period of time in which strong winds are pos- sible, it is recommended that the storm brackets be pulled out to the extended storm ready posi- tion before leaving home. Window Installation StormPlus and Structural Installations...
  • Page 12: Step Four − Final Installation Procedures

    Do not apply too much as it is possible to bow the jambs. Now insulate loosely around the window with fiberglass insula- tion. See figure 13. 19970019 2012−04−10...
  • Page 13: Continuous Air Barrier Systems

    Flashing Method A1−Membrane Drainage System”. Refer to ASTM E2112−07 for other rough opening preparations that are more appropriate for your situation. Figure 14: Preparing the opening. 19970019 2012−04−10 www.marvin.com/ROprep for instructions “Window Rough Opening Prep and Window Installation StormPlus and Structural Installations...
  • Page 14 Figure 16: Flashing windows with casing in typical wood frame construction (non recessed masonry). NOTE: Figure 16 shows a window with casing but the flashing detail also applies to any clad window product. For installation in typical wood frame construction or brick veneer (non−recessed masonry openings), figure 16 shows the proper flashing detail in shingle style fashion.
  • Page 15: Removing Interior Stops, Liners And Fillers

    Some structural installations that use the “jamb pinning” method require the removal of interior stops before installing the window. This section details the removal of Ultimate Double Hung (UDH) jamb liners and Casemaster operator and stationary stops. More detailed information can be found in the Marvin Service Manual.
  • Page 16: Removing Sash

    Seek Assistance: Some sash on large windows are very heavy. Avoid injury by getting help to lift and position the window into the rough opening. For other products not shown here refer to the Marvin Service Manual or contact your Marvin representative.
  • Page 17: Ultimate Double Hung And Casemaster Operators Stormplus Iz4 Notice Of Acceptance Information

    Exact instructions for installing windows certified for use in Impact Zone 4 are not included in this publication. The installer/contractor MUST install the window(s) according to detailed drawings found in the Notice of Acceptance (NOA) to the Product Control Division of the Miami−Dade County Building Code Compliance Office (BCCO). You will be able to find the NOA drawings for each certified product on the Miami−Dade County website (exact URLs...