Choose a suitable location for mounting the convector. The location shall have
enough space and clearance as illustrated in Fig. 1.
WIDTH OF CONVECTOR
C
6 in
(15.3 cm)
Minimum
clearance to
adjacent
surface
E
6 in
(15.3 cm)
Fig. 1
Model
a
b
(cm)
(cm)
SGCB-1000
53.7
33.7
SGCB-1500
58.1
33.7
SGCB-2000
72.6
48.3
WALL MOUNTING INSTRUCTIONS
1.
Release the mounting bracket by pressing the locking brackets on both sides.
2.
Use the mounting bracket as a template by holding it against the wall as
illustrated in Fig. 1.
3.
Follow the dimensions specified in Fig. 1 and place mounting bracket in the
desired location.
4.
Mark the 4 screw holes. Place mounting bracket on the screw markings and
ensure the mounting bracket is perfectly level.
5.
Predrill holes and insert 4 wall anchors. Wall anchors are needed for
mounting on drywall or concrete walls. Ensure you use the proper anchors
for your wall type.
6.
Replace the mounting bracket and fasten it with screws (minimum 4 screws).
7.
Mount the convector to the mounting bracket and engage the 2 locking
brackets at the top. See Fig. 2.
Caution – high teMPerature, risk of fire. keeP eleCtriCal
Cords, draPery, furnishings and other CoMbustibles at least
3 ft (0.9 M) aWay froM the front of the heater and aWay froM
the side and rear of heater.
Warning – to reduCe risk of fire, do not store or use
gasoline or other flaMMable vaPors and liQuids in the
viCinity of the heater.
A
D
B
6 in
(15.3 cm)
Minimum
clearance to
adjacent
surface
E
Minimum
distance
to ground
C
d
(cm)
(cm)
12.2
7.8
9.8
14.6
11
13.2
Wall bracket
Wall
Fig. 2

ELECTRICAL WIRING

Warning: this ConveCtion heater is to be used on a 240 vaC
PoWer suPPly and grounded outlets.
e
(cm)
24.8
22.2
22.2
HEATER
Caution: turn off Main PoWer before beginning installation
to avoid eleCtriC shoCk.
WARNING: THE HEATER MUST bE INSTALLEd bY A
CERTIFIEd ELECTRICIAN ANd IN ACCORdANCE WITH
ALL LOCAL ANd NATIONAL ELECTRICAL COdES.
1.
Connect white colored neutral wire (N).
2.
Connect black colored live wire (L).
3.
Connect green colored ground wire. All connections using twist on wire
connectors. Put all wires properly into the junction box before replacing the
cover with the provided screw.
OPERATION
Adjust the wall thermostat (not included) to increase or decrease the
temperature setting.
MAINTENANCE
Warning: to reduCe the risk of fire or eleCtriC shoCk, alWays
sWitCh off the unit and Wait 10 Minutes to alloW it to Cool
before atteMPting any MaintenanCe or Cleaning.
It is recommended that the heater is cleaned periodically in order to avoid dust
blocking the grill and allow proper ventilation.
2
Convector
THERMAL CUT-OFF
PROTECTION
BLACK (L)
WHITE (N)
GREEN/YELLOW (G)