3. Control panel function

Panasonic Controller
The Controller is found as a separate unit internally installed for the Monobloc unit, on the Bi-Bloc system the controller is found on the internal Hydro module.
9
8
7
6
AUTO
HEAT
MON TUE WED THU FRI SAT SUN
5
COOL
ON
TANK
OFF
HEATER
4
FORCE
OPERATION
3
2
1
28
27
26
25
No Displays
1
Operation LED
2
Display of external room thermostat
3
Display if Solar (Hydro) active (if installed)
4
Indicator that back up heater is enabled ( ) or disabled
(nothing showing)
5
Hot-water tank operation display (ON / OFF)
6
Cooling operation display (ON/OFF), (if applicable)
7
Heating operation display (ON / OFF)
8
Auto Mode OFF/ON Indicator
This icon indicates auto mode OFF/ON operation.
Display of timer setting and time
9
Display of outside temperature
10
Display of Heat Pump water flow temperature
11
Indicator that back up heater for heat pump and electric immersion
12
heater for the hot water tank is operating (on/off)
Display for quiet mode (ON / OFF)
13
Display for system programming (ON / OFF)
14
Display for system status (ON / OFF)
15
16
Display for in service mode (Engineers use only)
* Note: As the same operator control panel is used for different devices, some functions may not apply for your device.
UK_MANUAL_B.indd 5
10
11
12
13
14
ACTUAL
HEATER
15
hr
BOOSTER
°C
QUIET
kwh
SETTING
16
hr
STATUS
°C
SERVICE
17
18
19
24 23 22 21 20
No
Button assignment
17
Operation button (ON / OFF)
18
Operating mode selection button
Use this button to select the operating mode required.
19
System status buttons
These buttons are used for a series of status queries. Proceed as
follows:
· Press the CHECK button for 5 seconds to switch to Status mode.
· Press the UP or DOWN button to open the following values:
1. Compressor operating frequency
2. Error code
3. Water inlet temperature
4. Water tank temperature
· Press the CANCEL button or wait 30 seconds to quit Status
mode.
20
Service button (Engineer use only)
Button for enabling the additional electric heater for the heat
21
pump. The additional electric heater can only be used if this
button is pushed. Note: If this button is not pressed, the additional
electric heater for the heat pump is only used for:
· Defrosting
· Device startup
· Frost protection mode
22
Holiday button
Quiet mode button
23
System programming buttons
24
These buttons are used to set temperature values.
Emergency heating mode button
25
This button allows the device to be operated in emergency heating
mode with the additional electric heater for the heat pump, e.g. if
the heat pump is defective.
Press the ON / OFF button to switch off emergency heating mode.
Timer programming buttons
26
These buttons are used to set the time and the weekly timer.
The system is turned off by an external switch.
27
Warning sign on display this is to say the following: Indicator
28
that DHW is stored at +60 ºC – WARNING "HOT"