The following tables provide the maximum distances for remote power via Cat5 twisted
pair when a port on the Passive CCTV Hub Plus is set to Pass-Thru Mode (500022) or
Power-Thru Mode (500024/500029).
Pass-Thru Mode (500022) – Two (2) Twisted Pairs
Voltage
Pcam (W) Vcam
12 VDC/AC
5
12VDC/AC camera
10
20
30
40
50
24 VAC
5
24VAC camera
10
20
30
40
50
28 VAC
5
24VAC camera
10
20
30
40
50
Passive CCTV Hub Plus Installation Guide
1
2
min (V) Dist Spec
max (Feet) Dist Spec
10.80
86
10.80
43
10.80
22
10.80
14
10.80
11
10.80
9
21.60
346
21.60
173
21.60
86
21.60
58
21.60
43
21.60
35
21.60
922
21.60
461
21.60
230
21.60
154
21.60
115
21.60
92
Page 15

Distance Tables

2
max (m)
28
14
7
5
4
3
113
57
28
19
14
11
302
151
76
50
38
30
5.