Thermal Protection; Output Capacity - paco SWR-3000VA Instruction Manual

Microprocessor control (cpu) automatic voltage regulator high & low voltage protection
Table of Contents

Advertisement

6. LOW & HIGH VOLTAGE PROTECTION
When output voltage is lower or higher than labeled voltage, AVR will turn
into self-protection state automatically ,the UNUSUAL RED indicator
flashes every one second and output voltage will be cut off.
When output voltage comply with labeled voltage, AVR will go into
automatic recovering state, the UNUSUAL RED indicator extinguishes.
Then DELAYING ORANGE indicator flashes every one second, the
system goes into delaying state. After delay, DELAYING ORANGE
indicator extinguishes and output voltage resume .

7. THERMAL PROTECTION

When the temperature of the transformer exceeds 130℃+/-5% , the
system will automatically turn into self-protection state, UNUSUAL RED
indicator will flash every one second and output voltage shut down. While
temperature is lower 70℃+/-5% , the system will recover automatically.
UNUSUAL RED indicator will extinguish, and output resume.
NOTE: Not equipped overheating Protection in standard configuration,
users should notify manufacturer and take special order if this function
is required.

8. OUTPUT CAPACITY

The automatic voltage regulator will switch off automatically if the total
wattage of the electrical appliances exceed the automatic voltage
regulator output capacity.
If this voltage is in the range of 190-250V, the regulator provides the
100% listed maximum output power. maximum output power will change
as the curve shown below.
P(%)
100
75
50
25
100
120
140
160
180
200
THE POWER CURVE OF OUTPUT
OUTPUT: 220V~
USE THE SAME CURRENT
FUSE FOR REPLACEMENT
220
240
260
280
7
U(V)
300

Hide quick links: