ITB ARCHIMEDE 3000 Operating Manual

Broadband amp

Advertisement

Quick Links

ITALAB reserves the right to revise and change any and all information included in this document.
Ediz./Rev.
ARC3000 -A/00
ARC3000-A/00
User's Manual
ARCHIMEDE 3000 AR
432
Page 1 of 40
Italian Technology of Broadcast
ARCHIMEDE
Operating Manual
20144 Milano Italy
Phone: (39) 02 90389417
Fax: (39) 02 23168389
E-mail: info@italab.it
Website:
Data
Motivo
(gg/mm/aa)
20/06/2011
First Edition
18/09/2014
Second Edition
3000
Via Casale 3/A
www.italab.it
Approvato da:
M.N.
M.N.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARCHIMEDE 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for ITB ARCHIMEDE 3000

  • Page 1 ITALAB reserves the right to revise and change any and all information included in this document. Ediz./Rev. Data Motivo Approvato da: (gg/mm/aa) ARC3000 -A/00 20/06/2011 First Edition M.N. ARC3000-A/00 18/09/2014 Second Edition M.N. User's Manual ARCHIMEDE 3000 AR Page 1 of 40...
  • Page 2: Warranty Service

    Damage caused by product misuse is NOT covered by warranty. Warranty Service The ARCHIMEDE 3000 is a high reliability equipment. Nevertheless, as any equipment which works 24 hours a day for years, some failures are possible. Because the reparation of the modules, inside the Amplifier, is very difficult on the field, we suggest in the event of any failure to contact our service.
  • Page 3: Table Of Contents

    Power on Start of transmission Stop sequence LCD display alarm screens FWR alarm SWR alarm Temperature alarm User Programming Programming clock Programming language Programming name Programming exit Schematic drawings and BOM User's Manual ARCHIMEDE 3000 AR Page 3 of 40...
  • Page 4: Safety Instructions

    DO NOT REPAIR THE ARCHIMEDE Component maintenance, replacement and internal adjustments must be made only by ITB qualified service personnel. Fuses In the event of fuses failure, only fuses with the same required current, voltage rating, and specified type should be used.
  • Page 5  Repairs may only be carried out by a person authorized by ITALAB.  The ARCHIMEDE 3000 must be switched off and the power cord disconnected from the AC source when removing the top cover. Climatic Conditions In order to have the best performance in term of power, life span, etc, the following parameters must be respected: ...
  • Page 6: System Overview

    The switching power supply, extremely compact and of excellent quality, is oversized for its final use. The ARCHIMEDE 3000 is run entirely by a powerful microprocessor that in real time controls all the important functions for an efficient work (ventilation, temperatures of the RF part, temperature of incoming and inner air, output power and reflected power).
  • Page 7: Technical Features

    Limitations of use can be applied in respect of operating frequency, transmitter power and/or channel spacing. Italab is not criminally and civilly liable for a not-legally authorized use. User's Manual ARCHIMEDE 3000 AR Page 7 of 40...
  • Page 8: Front Panel

    Pushing the button the Amplifier will go on standby mode and the output auxiliary power supply will be suspended START BUTTON: Pushing the button the pallet will go on operating mode and output auxiliary power supply will be received User's Manual ARCHIMEDE 3000 AR Page 8 of 40...
  • Page 9: Rear Panel

    220 Vac control output for the transmitter ( Max 1 A. ) Ground connector A.C. mains input 220 Volt A.C. mains input 220 Volt Switch disconnector Extraction of hot air RF section Extraction of hot air RF section User's Manual ARCHIMEDE 3000 AR Page 9 of 40...
  • Page 10: Internal Overview

    Italian Technology of Broadcast INTERNAL OVERVIEW OF EQUIPMENT COLD AIR INPUT GRID option COLD AIR INPUT VANS RF BOX INTERFACE RF BOX POWER SUPPLIES ( these may change from model to model) User's Manual ARCHIMEDE 3000 AR Page 10 of 40...
  • Page 11: Installation To Start Up

    Verify that the input power is not greater than 2 watts. The device will maintain constant the output power even in the presence of a greater power input. Excessive power input will damage the Equipment. User's Manual ARCHIMEDE 3000 AR Page 11 of 40...
  • Page 12: System Start Up

    Amplifier. This can trigger destructive electric arcs during the switch on/off system and thus cause damage that is not covered by the warranty. User's Manual ARCHIMEDE 3000 AR Page 12 of 40...
  • Page 13: System Block Diagram

    Italian Technology of Broadcast SYSTEM BLOCK DIAGRAM INTERNAL WIRING User's Manual ARCHIMEDE 3000 AR Page 13 of 40...
  • Page 14: Circuit Description

    Temperature, ……) and to assure the normal operation. Inside the board there are two DC/DC switching to deliver the low voltage power from main 48V for all analogue and digital circuits. User's Manual ARCHIMEDE 3000 AR Page 14 of 40...
  • Page 15: Analog Board

    This module performs an efficient regulation of the AC input 230 Vac to a lower DC 48Vac for RF pallet and log/analog boards. Being its efficiency very high, very little heat is produced in the regulation process. User's Manual ARCHIMEDE 3000 AR Page 15 of 40...
  • Page 16: Lcd Display Screens

    On the fourth line of the display will be displayed alternately for some seconds the date and time During the broadcast it is possible to see sequentially on the display, by pressing the start button, the parameters of the Amplifier and the Equipment data. User's Manual ARCHIMEDE 3000 AR Page 16 of 40...
  • Page 17: Stop Sequence

    At the end of the standby cycle on the display will show the written P u s h S T A R T a r t h h : User's Manual ARCHIMEDE 3000 AR Page 17 of 40...
  • Page 18: Lcd Display Alarm Screens

    If the “SWR” does not return within normal ranges, but will exceed the threshold of 10%, the “CPU” will begin the process of standby and the display will show the written A l a r m S W R i m i t a t i o n User's Manual ARCHIMEDE 3000 AR Page 18 of 40...
  • Page 19 5 times in a hours the Amplifier will stop. To restart the Amplifier turn off for some seconds the main power supply 230 Volt and then turn it on. User's Manual ARCHIMEDE 3000 AR Page 19 of 40...
  • Page 20: User Programming

    When you enter the correct password the display will show the written P r o g r a m m i n g C U S T O M E R P u s h S T A R T User's Manual ARCHIMEDE 3000 AR Page 20 of 40...
  • Page 21: Programming Clock

    C L O C K programming clock In this situation by pressing the start button you go back to previous menu while by programming language pressing the stop button it switches at next menu User's Manual ARCHIMEDE 3000 AR Page 21 of 40...
  • Page 22: Programming Language

    By this time the writing will be on display in the selected language For the French language P r o g r a m m i L A N G U A G E F R A N C A I User's Manual ARCHIMEDE 3000 AR Page 22 of 40...
  • Page 23: Programming Name

    PROGRAMMING NAME P r o g r a m m i n g N A M E User's Manual ARCHIMEDE 3000 AR Page 23 of 40...
  • Page 24 In this situation by pressing the stop button it switches to menu while by pressing the start button you enter the programming exit menu and on the display will be shown the written User's Manual ARCHIMEDE 3000 AR Page 24 of 40...
  • Page 25: Programming Exit

    P U S H S T A R T In this situation by pressing the stop button it switches to previous menu while by pressing the start button you programming exit enter the menu User's Manual ARCHIMEDE 3000 AR Page 25 of 40...
  • Page 26 Italian Technology of Broadcast SCHEMATICS DRAWINGS AND BOM RF BOX User's Manual ARCHIMEDE 3000 AR Page 26 of 40...
  • Page 27: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 27 of 40...
  • Page 28: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 28 of 40...
  • Page 29: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 29 of 40...
  • Page 30: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 30 of 40...
  • Page 31: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 31 of 40...
  • Page 32: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 32 of 40...
  • Page 33: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 33 of 40...
  • Page 34 Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 34 of 40...
  • Page 35: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 35 of 40...
  • Page 36: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 36 of 40...
  • Page 37: User's Manual

    Italian Technology of Broadcast ANALOG User's Manual ARCHIMEDE 3000 AR Page 37 of 40...
  • Page 38: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 38 of 40...
  • Page 39: User's Manual

    Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 39 of 40...
  • Page 40 Italian Technology of Broadcast User's Manual ARCHIMEDE 3000 AR Page 40 of 40...

Table of Contents