CLEAN CHEMICAL FEED FILTER & FOOT VALVE:
(If so equipped)
Part of the optional Auto Fill & Chemical Feed system, the Filter & Foot Valve is on the end of the chemical
feed hose that is placed in the chemical jug as part of the chemical feed system.
Regularly examine the filter and clean as needed.
To test the Foot Valve:
• Remove the Filter & Foot Valve from the end of the chemical feed hose and rinse in fresh water.
• Blow through the valve from the filter side of the barb.
o If the Foot Valve is functioning, air should move freely from the filter side, but will not flow from
the barb side of the filter.
o If valve is not functional, clean or replace as needed.
Heavy chemical build-up can be removed with a mild acid rinse and/or the use of a brush and compressed
air.
CLEAN VACUUM SHUTOFF ASSEMBLY SCREEN:
Inside the recovery tank, on top of the stand pipe, is the Vacuum Shutoff Assembly. It functions to prevent
debris and water from being sucked into the vacuum motors. Operating the MX3-500 without the Vacuum
Shutoff Assembly or with a poorly maintained assembly will greatly decrease the life of the vacuum motors
and will void the warranty.
If debris builds up on this filter, it will reduce the vacuum air flow and may cause a significant decrease in the
rate of water recovery. If debris prevents the float ball from moving or seating inside the assembly, it may not
stop the airflow when the tank fill with water, and the water will be sucked into the vacuums and blown out
the exhaust. Use defoamer to prevent foam or moisture from entering vacuums (See Page 14).
To clean:
• Do not pull up on top of cap. Carefully pull up from the bottom of filter cap assembly to pull the
assembly off of the stand pipe. Then pull float off of riser pipe.
• Pull fibers and lint off and rinse filter cap assembly and float with clean water.
• Place the float back on the riser pipe then push the filter cap assembly back onto the stand pipe and
replace the recovery tank lid.
Chemical Feed Hose
Filter & Foot Valve
PDE100-11P
Vacuum Shutoff
Assembly
Filter Cap Assembly
Vacuum Shutoff Float
Flow Direction
28
Flow Direction

Advertisement