Troubleshooting –
Nautilus MX3-500
Problem
Cause
Machine not
Building circuit breaker tripped.
turning on -
Faulty power cord
No power
Faulty switches or internal wiring
Solution
Pump
Building circuit breaker tripped.
not running
Pump circuit breaker tripped
Faulty power cord
Faulty switches or internal wiring
Pump motor breaker tripped
Pump motor faulty
Pump seized - trips breaker
Low Solution
Jets too large for pressure desired
Pressure
Jets worn allowing too much flow
And / or
Solution inlet filter plugged
Pulsation
Hose from solution tank restricted
Pump intake hose or fittings
leaking
Pressure regulator sticking
Pressure regulator faulty
Filter screen or jets plugged on
tool
Solution tank empty
Pump not primed
Priming Valve Stuck Open
Pump faulty
Pressure Gauge faulty
Tool valve faulty
Quick connects or hoses restricted
Can't connect
Pressure in lines
solution hose
Quick connects faulty
to machine
Wrong style/size quick connects
*
To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by
experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
Solution
Reset breakers or move cords to other outlets
Replace cord (AX33)
Check wiring & test switches - Repair as needed *
Reset breakers or move cords to other outlets
Reset breaker – Check available circuit power & pump
Replace cord (AX33)
Check wiring & test switches - Repair as needed *
Push in reset button on pump motor &/or external breaker
Replace pump motor (PT066)
Repair or replace pump head & bearing (PT065) - Check
motor and/or replace complete pump & motor assy. (AP52)
Check jets size & flow rates use smaller jets or lower
pressure
Replace jets
Clean or replace filter
Repair or replace hose
Repair or replace hose. Tighten clamps or replace fittings
Lube o-rings on regulator shaft – PAGE 33
Repair or replace pressure regulator / unloader (PT017)
Clean out filter or jets
Add water to tank - Check & repair auto fill assembly
Perform pump priming procedure
Repair or replace the Priming Valve
Repair or replace pump (PT065 or AP52)
Replace gauge (PT063)
Repair or replace valve
Clean out or replace quick connects and/or hoses
Release pressure
Replace quick connects (AH101B, AH102B)
Replace quick connects to match connects on machine