DISCONNECTED SIGNALS

If without obvious reason the display for the main unit
goes blank or "
" is displayed, press and hold
[CHANNEL] to enforce an immediate search.
If that fails, check:
- All weather instruments are still in place.
- The batteries of the main unit and individual weather
instruments are still good. Replace them if necessary.
Press and hold [CHANNEL] to enforce an immediate
search afterwards.
- The transmission is within range and path is cleared of
obstacles and interference. Shorten the distance if
necessary.
Then press and hold [CHANNEL] again. The main unit will
start searching for all previously locked weather
instruments.
If you want to add a new sensor, press the [RESET]
button on the new sensor and then press [CHANNEL] to
enforce the main unit to search.
NOTE 1. Do not reset the sensors after the main unit has
locked those sensors, otherwise the main unit
will no longer receive the signal from those
sensors.
2. If you have disconnected signals, you cannot
clear the memory.

THE RESET BUTTON

This button is only used when the system is operating in
an unfavorable way or malfunctioning. Use a blunt stylus
to hold down the button. The main unit will return to all
default settings and start searching for signals again.
Before resetting the main unit, you should do the same
for all weather instruments to ensure correct transmission
and reception of signals. Then press [RESET] on the
main unit.

MAINTENANCE

When handled properly, this unit is engineered to give you
years of satisfactory service. Here are a few product care
instructions:
1. Do not immerse the unit in water. If the unit comes in contact
with water, dry it immediately with a soft lint-free cloth.
2. Do not clean the unit with abrasive or corrosive materials
Abrasive cleaning agents may scratch the plastic parts
and corrode the electronic circuit.
3. Do not subject the unit to excessive: force, shock, dust,
temperature, or humidity. Such treatment may result in
malfunction, a shorter electronic life span, damaged
batteries, or distorted parts.
4. Do not tamper with the unit's internal components. Doing
so will terminate the unit's warranty and may cause
damage. The unit contains no user-serviceable parts.
5. Only use new batteries as specified in this instruction
manual. Do not mix new and old batteries as the old
batteries may leak.
6. Read this instruction manual thoroughly before operating
the unit.

SPECIFICATIONS

Temperature
Proposed Operating Range : Indoor ..... 23˚F to 122˚F
Resolution
(indoor and outdoor)
Relative Humidity
Measuring Range
(indoor and outdoor)
Resolution
(indoor and outdoor)
Dew Point Temperature
Measuring Range
Resolution
(indoor and outdoor)
Barometric Pressure / Trend
Measuring Range
Resolution
Wind Speed
Measuring Range
Resolution
Wind Direction
Measuring Range
Digital Resolution
Graphical Resolution
Wind Chill Temperature
Measuring Range
Resolution
Rainfall
Daily and Cumulative
Measuring Range
Rainfall Rate
Measuring Range
Daily and Cumulative
Resolution
Rainfall Rate Resolution
WMR968 :
Weight
Dimension
Power
Power backup
7
(-5˚C to 50˚C)
: Outoor ..... -4˚F to 140˚F
(-20˚C to 60˚C)
: 0.2˚F (0.1˚C)
: 2 to 98% RH
: 1% RH
: Indoor ..... 32˚F to 120.2˚F
(0˚C to 49˚C )
: Outoor ..... 14˚F to 140˚F
(-10˚C to 60˚C)
: 2˚F (1˚C)
: 795 to 1050 mb
(23.48 to 31.01 inHg)
: 1 mb (0.03 inHg)
: 0 to 125.3 mph (0 to 56 m/s)
: 0.4 mph (0.2 m/s) (typical)
: 0˚ to 359˚ (Degrees)
: 1˚ (typical)
: 10˚
: -61.6˚F to 140˚F (-52˚C to 60˚C)
: 2˚F (1˚C)
: 0 to 393.7 in (0 to 9999 mm)
: 0 to 39.37 in/hr (0 to 999 mm/hr)
: 0.04 in (1 mm)
: 1mm/hr (0.04 m/h) typical
: 18 oz (505 g)
: 8 (L) x 5.5 (W) x 1.5 (H) in
(204 x 139 x 39 mm)
: 12V AC / DV adapter
: 4 x UM3 - "AA" size alkaline
batteries