#1
Our
When The Cast Iron Burner Burns Yellow or Not At All What Do I Do?
If your burner does not burn, blows out, burns yellow, or there's a flame
inside the ventura, you need to check the burner ventura for any
obstructions. Dirt Dobers, Spiders and other insects will build a nest inside
the burner ventura blocking air and gas flow.
KEEP AIR SHUTTER CLOSED AFTER EACH USE.
How To Clean
1. Remove the hose from the burner using a 7/16" wrench.
2. Insert a small rod in the hole that the hose was removed from.
3. Hold the burner up to a light looking into the hole that the hose was
removed from to see any obstructions.
4. If burner has not cleared flush with water.
5. Once the burner has been cleared, reassemble
the burner (air shutter, spring, hose.)
When a flame occurs inside the ventura this is caused by a
blockage and could cause damage to the hose assemble.
SAFE STORAGE & MAINTENANCE
• Always disconnect your gas cylinder after using your cooker.
• Always allow your cooker to cool completely before handling.
• Always cover and store your cooker in a protected area.
• If rusting occurs, use steel wool to clean or buff the affected area.
• The exterior of your cooker may be touched up by using a high temperature-resistant
paint.
• Coat the cooker stand with cooking oil after the unit has cooled.
• Check the regulator, hose, and burner parts, air shutter and ventura section carefully
before and after each use for any sign of wear.
• Always turn gas OFF at the gas cylinder valve prior to inspecting parts.
• Before each use of the cooker, check and clean the burner/venturi tubes for insects and
insect nests. A clogged tube can lead to a fire beneath the cooker.
• When the cooker is not in use, the gas must be turned OFF at the supply cylinder.
• Indoor storage of the cooker is permissible only if the cylinder is disconnected and
removed from the cooker.
• Cylinders must be stored outdoors, out of the reach of children, and must not be stored in
a building, garage, or any other enclosed area.
• The cylinder supply system must be arranged for vapor withdrawal.
• Always store the cooker in an area where the temperature won't exceed 125°F, and
Do Not store a spare cylinder on, or near, your cooker stand, or place connected gas
cylinder under the cooker stand. Always keep the gas cylinder 18 inches away from
the cooker stand.
Asked Question
Ventura
4
Need help?
Do you have a question about the MB10 and is the answer not in the manual?
Questions and answers