Organization of this manual This manual describes the features and operation of the Sound Level Measuring Amplifi er NA-42. The manual contains the following sections. Outline Gives basic information on the confi guration and features of the unit, and contains a block diagram.
Page 4
To conform to the EU requirement of the Directive 2002/96/EC on Waste Electrical and Electronic Equipment, the symbol mark on the right is shown on the instrument.
FOR SAFETY In this manual, important safety instructions are specially marked as shown below. To prevent the risk of death or injury to persons and severe damage to the unit or peripheral equipment, make sure that all instructions are fully understood and observed.
Precautions Operate the unit only as described in this manual. Protect the unit from shocks and vibration. Be especially careful not to touch the microphone membrane to avoid damage. The membrane is an extremely thin metal fi lm which can be damaged easily. Do not use the unit with a different microphone/preamplifi er from the one indicated on the name plate of the unit.
Page 7
Caution Some pins of the INPUT connector carry a high voltage. To prevent the risk of electric shock, never insert a metal clip or any other pointed object into the input connector.
Contents Organization of this manual ............i FOR SAFETY ................iii Precautions ..................iv Outline ....................1 Controls and Features ..............4 Front Panel ................4 Rear Panel ................8 Display ................... 10 Preparations ..................13 Power Supply ................13 Inserting Batteries ..............13 AC Adapter ................14 Microphone and Preamplifi er Connection ........15 Calibration ................20 1) Electrical calibration ............20...
Page 9
Bar Graph Display Range (20 dB/50 dB) Setting .....46 Menu Settings ................47 External Filter Setting .............52 Backlight On/Off ..............53 Comparator ...................54 Serial Interface ................58 Transfer Protocol ..............58 Local Mode/Remote Mode .............59 Transfer Sequence ..............61 Error Processing ..............63 Control Operation in Remote Mode ........63 Command Format ..............64 Commands ................67 Communication With Multiple Units Using SC-31 ....78...
Outline The NA-42 is a sound level measuring amplifi er covering a wide frequency range and level range. It allows connection of various types of microphones such as the low-noise microphone UC-34P or the 100-kHz range microphone UC-29. For general acoustic measurements and for environmental measurements, selectable frequency weighting (A, C, and FLAT) and time weighting char- acteristics (FAST, SLOW, IMPULSE) are provided.
Page 12
Outline Connector E OVER OVER CAL signal Input A, C -10 dB +10 dB +10 dB +10 dB OVER FLAT -20 dB +20 dB +20 dB FLAT AC OUT CAL ADJ 20 Hz 20 kHz External Antialiasing filter OVER filter FROM FILTER FILTER...
Page 13
Outline Example: Sensitivity -29.9 to -20.0 Adjustment by CAL ADJ (Span of adjustable range: 10 dB) 0 dB 0 dB 0 dB 0 dB -10 dB +10 dB +10 dB +10 dB -20 dB +20 dB +20 dB Main Unit Gain Diagram...
Controls and Features Front Panel Handle SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE LEVEL RANGE key Display A/C/FLAT key 20dB/50dB 20 dB/50dB key SENS key CAL key FAST/SLOW/IMP key FAST /SLOW SENS /FLAT Setting up/down /IMP Sensitivity control keys MENU...
Controls and Features FAST/SLOW/IMP key Selects the time weighting characteristics. Available settings are FAST, SLOW, and IMP (IMPULSE). Sensitivity control Serves to adjust the unit to match the microphone sensitivity. 20 kHz key Switches the low-pass fi lter (LPF) on and off. When the fi lter is on, sig- nal components above 20 kHz are sharply attenuated.
Controls and Features 20 Hz key Switches the high-pass fi lter (HPF) on and off. When the fi lter is on, signal components below 20 Hz are sharply attenuated. Lp/Lmax/Lpeak key Switches the measurement mode to sound pressure level L , sound level maximum L , or peak sound pressure level L...
Page 17
Controls and Features Caution To prevent the risk of electric shock, never insert a metal clip or any other pointed object into the input connector. Setting up/down keys These keys are used for setting the microphone sensitivity or for mak- ing a selection from a menu.
Controls and Features Rear Panel BATT BOX Battery holder Battery holder button AC OUT FILTER AC OUT connector LOCK UNLOCK External filter connectors FROM DC OUT FILTER DC OUT connector Name plate EXT 6V PREAMP ±12V ±45V External power supply FILTER connector SERIAL...
Page 19
Controls and Features Name plate The serial number of the unit is shown here. External power supply connector The dedicated AC adapter NC-98A is connected here. Comparator output This is an open-collector output with an A contact and COM contact. PREAMP power selector Selects ±12 V or ±45 V as power supply voltage for a connected pream- plifi er.
Controls and Features Display INSERT COMP REMOTE COMP REMOTE Battery indicator INSERT UNDER OVER UNDER OVER Calibration value Level range Level range (upper limit) (lower limit) Bar graph indicator PEAK MAX OVER PEAK MAX OVER Units Measurement value readout FAST SLOW Time weighting Frequency weighting...
Controls and Features Bar graph indicator Corresponds to the level of the input signal. PEAK MAX OVER "MAX" is shown here if the L function is selected. When the L peak function is selected, "PEAK" is shown. If an overload condition has occurred for either L or L , the indi- peak...
Page 22
Controls and Features Level range (lower limit) The lower limit of the level range is shown here. When the bar graph range is 50 dB, the value shown here corresponds to (level range -50 dB). When the bar graph range is 20 dB, the value shown here corresponds to (level range -20 dB).
Important · While inserting or removing batteries, support the battery holder by hand. NA-42 Battery holder · Take care not to insert batteries with wrong polarity. · While not using the unit, the batteries should be removed.
Preparations Battery life Alkaline batteries LR14 approx. 14 hours Manganese batteries R14P approx. 6 hours • The above values were determined under the following conditions. 20°C 50% RH, microphone UC-53A, preamplifi er NH-17, power supply for preamplifi er ±12 V, backlight OFF, communications OFF, continuous operation.
Preparations Microphone and Preamplifi er Connection The proper selection of microphone and preamplifi er depends on various factors, such as the level to be measured, frequency range, purpose of the measurement, etc. (For details, see the section "Technical Reference" start- ing on page 81.) Connect the microphone/preamplifi er to the INPUT connector.
Page 26
Microphone UC-53A Preamplifier NH-17 2. Confi rm that the NA-42 is turned off. Then connect the preamplifi er to the NA-42 with the cable of the preamplifi er. Microphone/preamplifier If you want to extend the cable, use the optional condenser micro- phone extension cable series EC-04.
Page 27
If the micro- phone is accidentally dropped, sensitivity and frequency response may be impaired. 2. Confi rm that the NA-42 is turned off and that the PREAMP power selector on the rear panel is set to ±12 V. BATT BOX...
Page 28
Preparations 3. Using the optional condenser microphone extension cable series EC- 04, connect the preamplifi er to the NA-42. Condenser microphone extension cable series EC-04 Length Length Model Model EC-04C EC-04 30 m (reel section) + 5 m (link section)
Page 29
Adapter UA-12 Preamplifier NH-05 2. Confi rm that the NA-42 is turned off. Then connect the preamplifi er to the NA-42 with the cable of the preamplifi er. If you want to extend the cable, use the optional condenser micro- phone extension cable series EC-04.
1. Turn the unit on. 2. Press the SENS key. 3. Use the setting ( , ) keys to set the value for the microphone (preamplifi er). SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB SENS key CAL key FAST...
Page 31
Preparations The sensitivity setting is the microphone sensitivity plus the pream- plifi er loss. The microphone sensitivity is the value given on the calibration chart attached with the microphone (see below). The microphone sensitivity 37564 CALIBRATION CHART FOR CONDENSER MICROPHONE UC-52 01-02-03 Date Open Circuit Sensitivity...
Page 32
Preparations Note When the 0.1 dB readout resolution has been chosen with menu 3, the sensitivity setting range extends to fi rst decimal place. When the 0.01 dB readout resolution has been chosen, the sensitivity setting range extends to second decimal place. If the sensitivity has been set with second decimal place and the readout resolution is then switched back to 0.1 dB, the second decimal place sensitivity...
Page 33
Preparations 7. Use the supplied screwdriver to adjust the sensitivity control on the front panel to the calibration value (under 6 dB of the level range value). Calibration Value Level range value Measurement value FAST Calibration example for level range 100...
1. Turn power to the pistonphone NC-72 or sound calibrator NC-74 off. 2. Turn power to the NA-42 on. 3. Press the SENS key on the front panel. SOUND LEVEL NA-42...
Page 35
Preparations 4. Use the setting ( , ) keys to adjust the sensitivity. The microphone sensitivity is the value given on the calibration chart accompanying the microphone (see below). The microphone sensitivity 37564 CALIBRATION CHART FOR CONDENSER MICROPHONE UC-52 01-02-03 Date Open Circuit Sensitivity Signature...
Page 36
Preparations 5. Press the SENS key on the front panel to return to the measurement screen. 6. Use the LEVEL RANGE keys to set the level range to "100" if the NC-74 is used, or to "120" if the NC-72 is used. Level range setting Select FAST with NC-74: 100...
Page 37
JIS C 1515-1991 SER.NO Sound calibrators FREQUENCY 250Hz Calibration class 0L SOUND PRESSURE LEVEL 114. dB 11. Turn power to the NA-42 and pistonphone NC-72 or sound calibrator NC-74 off. 12. Remove the microphone very carefully and slowly from the cou- pler.
Page 38
Adjust the NA-42 as follows, depending on the mi- crophone in use. Calibration value Nominal outer...
The NA-42 allows calibration using the "Insert CAL" method. For this method, a dedicated preamplifi er is used. 1. Turn power to the NA-42 off and connect the Insert CAL preampli- fi er NH-08 and the microphone. 2. Turn power to the NA-42 on.
Page 40
Preparations 8. Press the CAL key to activate the calibration mode. INSERT Calibration value Level range value Measurement value FAST Calibration example for level range 100 Measurement parameters are automatically set to C weighting and FAST. 9. Use the supplied screwdriver to adjust the sensitivity control on the front panel to the calibration value (94.0 dB in the example shown above).
Page 41
A COM NA-42 rear panel This is an example for the level range 120 dB. 1. Before making any connections, turn power to the NA-42 and to the external device off. Then connect the device and turn power on. SOUND LEVEL...
Page 42
Preparations 2. Set the level range to 120 and press the CAL key. Level range value Measurement value FAST 3. The AC OUT and DC OUT connectors carry a signal that corre- sponds to the displayed measurement value. (The AC output signal is a 1 kHz sine wave signal.) Use this signal to calibrate the external device.
Preparations Using a Tripod When mounting the microphone on the optional tripod, fi rst fasten the mi- crophone holder to the tripod. Microphone/preamplifier Connector Microphone holder EC03001 All-weather windscreen tripod ST-81 Microphone holder UA-90 NH-17, NH-11, NH-12 EC03001 NH-01, NH-04, NH-05, NH-06, NH-34 The EC03001 is supplied with the condenser microphones EC-04, EC-04A, and EC-04B.
Preparations Using a Windscreen When making outdoor measurements in windy weather or when measuring air conditioning equipment or similar, wind noise at the microphone can cause measurement errors. To prevent this, an optional windscreen can be mounted to the microphone. For details on the effect of the windscreen upon the measurement, please refer to "Technical Reference"...
The unit can be tilted by fl ipping out the prop-up feet. Tilt the feet until they snap in place. Important When using the prop-up feet, do not place objects on top of the NA-42 and do not push down on the unit. Do not push Prop-up feet...
Measurement Power-On Important Preamplifi er power supply Normally, the PREAMP power selector on the rear panel should be set to ±12 V. If wishing to set the selector to ±45 V, fi rst make sure that the preamplifi er (microphone) is compatible with this voltage.
Page 47
Measurement When the unit is turned on, the same settings as used before the unit was turned off are reestablished (resume function), and measurement starts. Settings memorized by Settings not memorized by resume function resume function Level range Calibration High-pass filter Backlight status Low-pass filter Microphone sensitivity...
Measurement Level Range Setting Setting procedure Use the LEVEL RANGE keys to select an appropriate setting, where the OVER or UNDER indication does not appear in normal operation. If the input signal level is too high for the selected range, the indication OVER appears.
Available frequency weighting settings are A weighting, C weighting, and FLAT. Setting procedure Press the A/C/FLAT key to select the desired setting. Each push of the key cycles through the following settings: A FLAT SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB Frequency weighting FAST /SLOW...
Available time weighting settings are FAST, SLOW, and IMP (impulse). Setting procedure Press the FAST/SLOW/IMP key to select the desired setting. Each push of the key cycles through the following settings: FAST SLOW FAST. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB Time weighting FAST FAST/SLOW/IMP...
L (peak sound pressure level) peak (sound level maximum) 1. Press the Lp/Lmax/Lpeak key to select the L setting. The indica- tion "MAX" appears on the display. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST SENS /SLOW /FLAT...
Page 52
Measurement 4. The RESET key can be used to reset the hold value. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST /A/C /SLOW SENS FLAT /IMP MENU 20Hz 20kHz 20Hz 20kHz (LIGHT) INPUT POWER Lp/Lmax /Lpeak EXT FILTER RESET...
Page 53
3. If the hold value has caused overload, PEAK OVER is shown. PEAK OVER SLOW 4. The RESET key can be used to reset the hold value. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST /A/C /SLOW...
Setting procedure Press the 20 kHz key to toggle the 20 kHz low-pass fi lter between ON and OFF. When the setting is ON, signal components above 20 kHz are sharply attenuated. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST...
Setting procedure Press the 20 Hz key to toggle the 20 Hz high-pass fi lter between ON and OFF. When the setting is ON, signal components below 20 Hz are sharply attenuated. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST...
Press the 20 dB/50 dB key to toggle between the two settings. Each push of the key switches between the following settings: 20 dB 50 dB 20 dB etc. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB 20 dB/50 dB key...
Measurement Menu Settings Settings for preamplifi er gain, SOUND LEVEL insert ON/OFF, measure- NA-42 MEASURING AMPLIFIER LEVEL RANGE ment value readout resolu- tion, serial communication, and comparator measurement 20dB/50dB conditions are made using FAST /SLOW menus. SENS /FLAT Setting up/down keys...
Page 58
Measurement Each push of the MENU (LIGHT) key cycles through the following menu numbers: 4.0 (4.1 4.2)* 5.0 (5.1 5.4)* measurement screen *1 Appear when 9600 or 19200 was set with menu 4.0. *2 Appear when menu 5.0 is set to ON. 3.
Page 59
Measurement Menu setting contents Menu 1 Preamplifi er gain 0 dB/20 dB When set to 20 dB, pin E of the INPUT connector carries a micro- phone bias voltage of 30 V. 0 dB : This setting should be selected normally. 20 dB : Select this setting if the UC-34P (UC-34, NH-34) is con- nected and low-level measurement is to be carried out.
Page 60
Sets the Multi-Channel Adapter SC-31M or SC-31S to ON or OFF. SC-31M/SC-31S is not used. Communication between a computer and a single NA-42 can be carried out. SC-31M/SC-31S is used. Communication between a com- puter and multiple NA-42 units can be carried out.
Page 61
Measurement Note When menu 4.0 is set to OFF, menus 4.1 and 4.2 are not shown. Menu 5.0 Sets the comparator to ON or OFF. Comparator function is disabled. Comparator function is enabled. Menu 5.1 Sets the comparator level. The comparator level setting range is 0 to 180 dB, in 1-dB steps. Menu 5.2 Sets the comparator delay time.
EXT 6V PREAMP ±12V ±45V FILTER SERIAL COMP OUT A COM 2. Press the EXT FILTER key to route the signal through the external fi lter. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST SENS /SLOW /FLAT /IMP MENU 20Hz...
Press and hold the MENU (LIGHT) key for at least 2 seconds to set the LCD backlight to ON or OFF. When set to ON, the backlight will make the screen easy to read also in dark locations. SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST...
The comparator function is based on the sound pressure level L , not on the peak sound pressure level L peak To turn the comparator function ON or OFF, SOUND LEVEL NA-42 use menu 5.0. MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST SENS...
Page 65
Comparator COMP While comparator function is operating, the indication COMP is shown. In the bar graph indication, the bar corresponding to the comparator refer- ence level remains constantly on. For example, when the comparator level is set to 75 dB, the 75 dB point on the bar graph scale lights up.
Page 66
Comparator Auto reset function The auto reset function is set with menu 5.3 ( "Menu Settings", p. 51). When set to ON, the comparator output, once triggered, will be reset after the time set with menu 5.4 when the sound pressure level remains below the comparator level for an extended time.
Page 67
Comparator Reset operation When the comparator output was activated, it can be reset in three ways. (1) Auto reset As described above, when auto reset is ON, the comparator output will be reset automatically after activation when the auto reset time has elapsed.
Serial Interface The NA-42 incorporates a serial interface that can be used to set measurement parameters and control measurement using commands sent from a computer. Measurement results can also be sent to the computer. Using SC-31M or SC-31S adapters (option), a single computer can be used to control up to 16 NA-42 units.
Serial Interface Local Mode/Remote Mode Local mode In this mode, the controls on the panel of the NA-42 are used to op- erate the unit. Immediately after being turned on, the unit is always in local mode. Remote mode In this mode, the NA-42 operates in response to commands sent from a computer.
Page 70
Serial Interface 1:N connection When connecting multiple NA-42 units (up to 16) to one computer, the optional SC-31M/SC-31S adapters and LAN cables (generic 10Base-T cable) are required. Computer NA-42 NA-42 NA-42 NA-42 SC-31M SC-31S SC-31S SC-31S SC-31S LAN cable LAN cable...
Transfer Sequence Sending of commands In order to control the NA-42 from a computer or to retrieve measurement data, certain commands must be sent to the NA-42. The data exchange must be performed according to certain rules, to ensure that both the NA-42 and the computer recognize the commands and data properly.
Page 72
Serial Interface Computer NA-42 RMT1**<CR><LF> Link established <ACK>READY<CR><LF> (Setting command) <CR><LF> <ACK>READY<CR><LF> Setting command (Data request command) <CR><LF> (Data) <EOT><CR><LF> Data request command RMT0**<CR><LF> Link terminated ** is the ID number. <ACK>: Control code 06 (acknowledge) <CR>: Control code 0D (carriage return) <LF>:...
Control code 15 Control Operation in Remote Mode While the NA-42 is in remote mode, only the MENU (LIGHT) key and RESET key are active. The MENU (LIGHT) key allows turning the display backlight on and off, and the RESET key in remote mode serves for switching back to...
Serial Interface Command Format Commands that can be used by the NA-42 consist of 3 characters (3 bytes), usually followed by a parameter which specifi es the action range of the com- mand. <CR> <LF> Command Parameter Terminator There are two types of parameters: •...
Serial Interface Command List Command Function See Page Select local mode/remote mode RMTn1n2n3 Get ID number and remote mode status RMT? RNGn Set level range Get level range status RNG? TMCn Set time weighting Get time weighting setting TMC? Set frequency weighting WGTn WGT? Get frequency weighting setting...
Page 76
Serial Interface Command Function See Page CMPn Set comparator function to On/Off Get comparator function status CMP? CMSn1n2n3n4n5n6n7 Make comparator function settings Get comparator function settings CMS? Get version information VER? PREn Set preamplifier gain to 0 dB/20 dB Get preamplifier gain and setting of rear-panel PRE? PREAMP power selector Set Insert CAL...
= 1 Remote mode n2 n3 = 00 to 15, FF Set ID number. NA-42 specifi ed by ID number receives the command. FF specifi es all connected NA-42. To send a setting command to all connected NA-42 units when using the SC-31M/SC-31S, use "n2n3=FF".
Page 78
Serial Interface TMC n Set time weighting for main processing FAST SLOW TMC? Get time weighting setting Output data format p<EOT><CR><LF> p corresponds to n of TMC WGT n Set time frequency weighting A weighting C weighting FLAT response WGT? Get time frequency weighting setting Output data format p<EOT><CR><LF>...
Page 79
Serial Interface SNS? Get sensitivity setting Output data format p1p2p3p4p5<EOT><CR><LF> For setting the sensitivity down to one decimal point when the readout resolution is set to one decimal point, p5 becomes "0". LPF n Set low-pass fi lter setting n = 0 n = 1 20 kHz LPF ?
Page 80
Serial Interface CAL n Set calibration mode n = 0 Calibration OFF n = 1 Calibration ON CAL? Get calibration mode status Output data format p<EOT><CR><LF> p = 0 Calibration OFF p = 1 Calibration ON BAT? Get battery capacity status Output corresponds to status of battery capacity indicator on display.
Page 81
Serial Interface · When readout resolution is set to two decimal points p1 p2 p3 p4 p5 p6,p7 <EOT><CR><LF> p1 to p6 : Indicated measurement value p4 : Taken as "." When the integer is 1 or 2 digits, the empty p1 and/or p2 part is padded with spaces.
Page 82
Serial Interface Set L MAX n (sound level maximum) function to On/Off n = 0 Maximum hold OFF n = 1 Maximum hold ON Get L MAX? function status Output data format p<EOT><CR><LF> p = 0 p = 1 active Set L PEK n (peak sound pressure level) function to On/...
Page 83
Serial Interface CMS n1 n2 n3 n4 n5 n6 n7 Make comparator function setting n1 to n3: Set comparator level to 000 to 180 n1 is the fi rst digit, n2 the second digit and n3 the third digit. When the setting value is only 1 or 2 digits, the empty part is padded with zeros.
Page 84
Serial Interface PRE? Get preamplifi er gain and setting of rear-panel PREAMP power selector p1p2<EOT><CR><LF> p1 corresponds to n of PREn p2 = 0 ±12 V p2 = 1 ±45 V INSn Set Insert CAL n = 0 n = 1 INS? Get Insert CAL setting Output data format...
Page 85
Serial Interface DOF Transfer Sequence Computer NA-42 DOF1<CR><LF> (Data) EOT<CR><LF> Continuous output of instantaneous value every 100 ms (0.1 seconds) (Data) EOT<CR><LF> <SUB> Output terminated The instantaneous value sound pressure level output updated every 0.1 seconds stops when <SUB> or DOF0<CR><LF> is input. Normally <SUB> should be used, because the chance for communication errors is lower.
Page 86
Serial Interface Allowable remote mode commands in various operation conditions indicates that command is allowed (valid). × indicates that command is not allowed (invalid). Normal Command Calibration Comparator peak operation measurement Content: Others related commands RMT0n2n3 × Content: Data related commands ×...
Page 87
Serial Interface Normal Command Calibration Comparator measurement peak operation Content: Others related commands (with ?) VER? × RMT? × BAT? × Content: Front panel key related commands (with ?) RNG? × TMC? × WGT? × LPF? × HPF? × EXT? ×...
Communication With Multiple Units Using SC-31 Using the optional SC-31M/SC-31S adapters, it is possible to connect up to 16 NA-42 units to a single computer. Connecting multiple NA-42 units (max. 16) to a computer Use SC-31M/SC-31S adapters (option) and LAN cables (generic 10BaseT cable)
Page 89
4. Send the RMT0** command from the computer to set the specifi ed NA-42 unit to local mode. 5. Repeat steps 2 to 4 with the ID number for any other NA-42 unit, as necessary. Note Before setting another NA-42 unit to remote mode, be sure to return the currently controlled NA-42 unit to local mode.
Page 90
When sending commands to all connected units, only commands for chang- ing settings are allowed. 1. Send the RMT1FF command from the computer to set all NA-42 units to remote mode (link established). 2. Use the necessary setting commands to control all NA-42 units.
Technical Reference Microphone and Preamplifi er Selection When making measurements using a condenser microphone and preamplifi er combination, suitable models must be selected according to the measurement level, frequency range, and other factors. Condenser microphones (sample listing) Type UC-53A UC-52H UC-34 (P) UC-29 UC-27...
Page 93
NH-11 2.5 m NH-04 UA-20 EC-04 2 m NH-12 2.5 m EC-04A 5 m NH-17A UA-20 NH-17 5 m EC-04B 10 m NA-42 NA-42 SOUND LEVEL MEASURING AMPLIFIER EC-04C 30+5 m LEVEL RANGE UA-20 20dB/50dB EC-04D 50+5 m NH-05 FAST...
Technical Reference Measurement range The frequency range and linear operation range depend on the microphone and preamplifi er. Frequency range The frequency range that can be measured depends on the microphone, as shown in the graph below. Microphone UC-24 UC-26 UC-27 UC-28 UC-29...
Technical Reference Microphone There are various ways to convert sound pressure changes into electrical signals. For acoustic measurements, the condenser (electrostatic) microphone principle is widely used, because it offers high stability, fl at frequency re- sponse, high sensitivity and allows compact dimensions. As an example, this manual describes the microphone UC-34.
Page 96
Technical Reference the upper frequency limit means that sensitivity is decreased. The tuning of microphone frequency response is achieved by opening a number of holes in the backplate in order to adjust the viscous resistance (damping characteristics) of the air that moves between the diaphragm and the backplate.
Page 97
Technical Reference The microphone UC-34 is made out of the following materials: titanium (chassis), titanium alloy (diaphragm), and silicone-impregnated and quartz- coated steatite (insulators). The main specifi cations of the microphone are shown in the table below. Main specifi cations of microphone UC-34 Bias voltage 200 V Nominal outer diameter...
Technical Reference Preamplifi er Since the capacitance of a condenser microphone is low (in the range of several picofarads to several tens of picofarads), its impedance is very high, especially at low frequencies. In order to achieve usable frequency response down to low frequencies, the load impedance as seen by the microphone must be very high (see equation 1).
Technical Reference Insert CAL By using the dedicated preamplifi er NH-08, the NA-42 allows highly accurate calibration comprising the microphone and preamplifi er (Insert CAL). Insert CAL function The microphone sensitivity is determined under the assumption that the mi- crophone is connected to a preamplifi er with infi nitely large input impedance and input capacitance of 0.
Technical Reference Extension Cable After impedance conversion by the preamplifi er, the signal from the micro- phone is fed through an extension cable to the sound level meter. The fol- lowing extension cables are available as options. Condenser microphone extension cable series EC-04 Model Length Length...
Page 101
Technical Reference 0.1 µF 500 m 40 nF 200 m 20 nF 100 m 10 nF 50 m 4 nF 20 m 2 nF 10 m 1 nF 500 pF 2.5 m 10 k 50 k 20 k 100 k Frequency (Hz) Preamplifier output voltage level (dB (re.
Technical Reference Windscreen During outdoor measurements, wind noise can falsify measurement results. To counter such problems, an optional windscreen should be mounted on the microphone. The characteristics of the windscreen WS-01 and WS-02 are shown in the fi gures below and on the next page. The attenuation of wind noise afforded by the windscreen is about 26 dB for sound level (A weighting) and 15 dB for sound pressure level.
Page 103
Technical Reference With WS-01 With WS-02 15 m/s 15 m/s 10 m/s 10 m/s 5 m/s 5 m/s 50 70 100 200 300 600700 1 k 50 70 100 200 300 600700 1 k Frequency (Hz) Frequency (Hz) Frequency response of wind noise measured with windscreen WS-01/WS-02 mounted to microphone With WS-01 20 30 50 70 100...
Technical Reference Infl uence of Background Noise When measuring a certain sound in a certain location, all other sound present at that location except the measurement target sound are background noise (also called background). Since the sound level meter will display the com- bination of target sound and background noise, the amount of background noise must be taken into consideration when determining the level of the target sound.
Technical Reference Frequency Weighting The NA-42 provides a choice between A and C weighting and FLAT fre- quency response. The electrical characteristics of the weighting circuitry are as shown below. FLAT FLAT C weighting C weighting LPF 20 kHz FLAT...
Technical Reference INPUT Connector The INPUT connector is a Tajimi Electronics 7-p connector (1008-23A10-7F). The pin assignment is as follows. A: Preamplifi er power supply +12 V / +45 V B: Ground C: Signal input D: Preamplifi er power supply -12 V / -45 V E: 30 V DC / ground / calibration signal INPUT connector as F: 60 V DC (microphone bias voltage)
T is performed. The result is divided by T and the square root is extracted. The circuit confi guration for performing the above mathematical operation looks as follows. E (rms) power of 2 Input voltage Output voltage The NA-42 uses digital processing to calculate the rms value.
Page 108
Technical Reference During noise level measurements, the level often fl uctuates drastically, which would make it diffi cult to evaluate readings without some kind of averag- ing. Sound level meters therefore provide the capability for index weighting (index averaging) using the rms circuit. The parameters of this weighting process are called the time weightings, determined by the time constant (see next page).
Page 109
Technical Reference Time weightings and time constant Time constant Time weightings Rise time Fall time FAST 125 ms 125 ms SLOW 35 ms 1.5 s The time weighting circuit of the = CR noise level meter performs index averaging on the square of the sound pressure signal.
Technical Reference Factory Default Settings The factory default settings are listed below. To reset the unit to these settings, turn the unit off, and then hold down the RESET key while turning the power on. (The rear-panel PREAMP power selector setting and the microphone sensitivity setting are not reset.) Factory default settings Level range (upper limit) 120 dB...
Technical Reference Displaying the Software Version To display the software version, turn the unit off, and then hold down the MENU (LIGHT) key while turning the power on. The software version is shown in the measurement value fi eld. Version information Software version display example Rack Mounting The unit can be mounted in a rack, using the four screw holes on the bot-...
CSV format suitable for further processing for example with a spreadsheet application. In conjunction with the optional adapter SC-31M or SC-31S, the software can control up to 16 NA-42 units connected to a single computer. The Software NA-42PB1 is designed to run under Microsoft Windows 95, or Microsoft Windows 98, Microsoft Windows 98SE, Microsoft Windows NT (Ver.4.0), Microsoft Windows Me, Microsoft Windows 2000, Microsoft...
Page 113
Technical Reference Main menu screen Measurement screen...
Specifi cations Measurement functions Sound pressure level L Sound level maximum L Maximum sound level value is held on measurement value readout. Peak sound pressure level L peak Peak sound pressure level value is held on measurement value read- out. Sampling frequency 250 kHz Frequency range 1 Hz to 100 kHz (approx -2 dB at 1 Hz, approx -3 dB at 100 kHz)
Page 115
Specifi cations Residual noise Input converted inherent noise A weighting: 1.5 µV rms or less C weighting: 1.5 µV rms or less Flat characteristics: 7 µV rms or less Flat (HPF 20 Hz, LPF 20 kHz): 2.5 µV rms or less Linearity range 60 dB Level range switching...
Page 116
Specifi cations Time weighting FAST, SLOW, IMPULSE RMS detection By digital processing Built-in fi lters High-pass fi lter (HPF): 3rd-order Butterworth fi lter, 20 Hz (-3 dB) Low-pass fi lter (LPF): 3rd-order Butterworth fi lter, 20 kHz (-3 dB) Calibration Electrical calibration using 1-kHz sine wave signal produced by internal oscillator Insert CAL function possible with dedicated preamplifi er NH-08...
Page 117
Specifi cations DC output BNC connector Output voltage: 6 V (at full-scale of range), 1 V/10 dB Output impedance: 50 Ω Load impedance: 10 kΩ or more External fi lter input BNC connector Output impedance: 600 Ω Input impedance: 100 kΩ Serial communication For setting control from computer and data output D-sub 9-pin male connector...
Page 118
Specifi cations Display Backlit LCD Numeric readout 5 digits, display range 70 dB second decimal place or fi rst decimal place, switchable Display update interval 1 s for fi rst decimal place readout resolu- tion 0.2 s for second decimal place readout resolution Bar graph Scale range 50 dB or 20 dB, update interval...
Page 119
Specifi cations Power requirements IEC R14 (size "C") batteries × 4 (R14P or LR14) Battery life LR14: approx. 14 hours R14P: approx. 6 hours * Measurement conditions Ambient temperature 23ºC, using microphone UC-53A and preamplifi er NH-17, preamplifi er power supply voltage ±12 V, backlight OFF, serial communication AC adapter NC-98A...
Page 120
Pistonphone NC-72 Sound calibrator NC-74 Preamplifi er (for vibration measurements) VP-26C NA-42 management software NA-42PB1 (for Microsoft Windows 95, Microsoft Windows 98, Microsoft Windows 98SE, Microsoft Windows Me, Microsoft Windows 2000, Microsoft Windows XP and Microsoft Windows NT (Ver. 4.0))
Specifi cations SOUND LEVEL NA-42 MEASURING AMPLIFIER LEVEL RANGE 20dB/50dB FAST /SLOW SENS /FLAT /IMP MENU 20Hz 20kHz (LIGHT) INPUT POWER Lp/Lmax /Lpeak RESET EXT FILTER Front BATT BOX AC OUT FILTER LOCK UNLOCK SOUND LEVEL SOUND LEVEL FROM MEASURING AMPLIFIER...