1 Introduction This meter is a convenient non-contact infrared thermometer with the functions of laser targeting, back light, data hold and auto power off… 2 Safety Information ▪ Please read the following information carefully before using the meter. ▪ Do not clean the meter using solvents. Warning: Do not point laser directly at eye or reflective surfaces.
Cautions: When ambient temperature changes quickly, wait 30 minutes to before taking measurements. Avoiding EMF(electro magnetic fields) from arc weld, induction furnace, etc… Do not leave the unit on or near high temperature objects. 3. Instrument Description ① Infrared sensor ②...
④ Measurement Display ⑤ Emissivity display ⑥ Back light indication ⑦ Data hold indication ⑧ °C temperature units ⑨ °F temperature units 4 Specifications Measurement range: -4°F to 518°F (-20°C to 270°C) Accuracy at ambient of 72°F (22°C) +/-(2% reading + 6°F(3°C)) Temperature measurement range:32°F to 122°F (0°C to 50°C) Resolution: 1°F (1°C) 6...
Emissivity: 0.95 Distance to Spot (D:S) Ratio: 6:1 Laser power: <1mW Over range indication: “OL” or “-OL” Auto power off: After 20 sec. 5. Operating Instructions Point the infra-red sensor at the object, and press the “SCAN” button. Release the “SCAN” button and the measured result will hold automatically.
Page 8
5-2 To measure the ambient temperature Press the “SCAN” button to start the unit. Press the “Tamb” button to select the ambient temperature measurement mode, and “Tamb” will appear on LCD. Now, press the “SCAN” button, the measured ambient temperature will be displayed on the LCD.
Page 9
6-1. Note: When the symbol “Tamb” appears, the measurement for object temperature is not available. NOTE: If an object surface is very slick, such as stainless steel, the emissivity from surface is low, and the measurement accuracy will be affected. An effective solution is that using the black adhesive - 4 - tape to cover the object surface, starting the measurement until the adhesive tape’s temperature is same as the object.
Other functions Back light: Press the key to turn on the backlight. Measurement unit (°C/°F) selection: Open the battery cover and take the battery out, shift the switch to select the measurement unit. 6. D:S ratio The thermometer has a visual angle and visual spot size; a drawing is shown as follows: 10...
Page 11
Make sure that the target is larger than the unit’s visual spot size. The smaller the target, the closer you should be to it. The relationship between distance and spot size is 6:1, the drawing as following: 11...
8 Replace batteries If the sign “ ” appears on the LCD display, it indicates that battery should be replaced. Remove the battery cover, and replace the exhausted batteries with new ones. 12...
Page 13
WARRANTY Sealed Unit Parts Co., Inc. warrants that it will repair or furnish without charge a similar product to replace any product which, within the specified warranty term after the date of sale by the Wholesaler, is proved to the satisfaction of Sealed Unit Parts Co., Inc.
Page 14
This warranty applies only to products which after shipment from the factory, have not been altered, changed, repaired, or treated in any manner whatsoever. This warranty to repair or replace is the only warranty either expressed, implied or statutory and is the only warranty being issued herein; Sealed Unit Parts Co., Inc.'s liability in connection with its products is expressly limited to the repair or replacement of defective parts.
Page 15
No representative of Sealed Unit Parts Co., Inc. has authority to change this warranty in any manner whatsoever. No attempt to repair or promise to repair or improve any part covered by this warranty by any representative of this company shall be effective unless signed by a properly authorized officer of Sealed Unit Parts Co., Inc.
Page 16
Sealed Unit Parts Co., Inc. (SUPCO) 2230 Landmark Place Allenwood, NJ 08720 USA www.supco.com info@supco.com 16...
Need help?
Do you have a question about the PIT6L and is the answer not in the manual?
Questions and answers