Specifications - Mitsubishi MXZ-8B140VA Technical & Service Manual

Table of Contents

Advertisement

3

SPECIFICATIONS

MXZ-8B140VA MXZ-8B140YA
MXZ-8B160VA MXZ-8B160YA
Service Ref.
Rated Cooling capacity
Rated power consumption *1
Operating current
Operating power factor
Starting current (Outdoor unit)
Rated Heating capacity
Rated power consumption *1
Operating current
Operating power factor
Starting current (Outdoor unit)
Breaker
Max. current (Outdoor unit only)
Power supply (phase, cycle, voltage)
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
*1 Electrical data is only for outdoor unit.
Conversion formula
[6.35mm
[9.52mm
[12.7mm
1/4 inch
3/8 inch
1/2 inch
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor
: D.B. 27°C (80°F), W.B. 19°C (66°F) Outdoor : D.B. 35°C (95°F), W.B. 24°C (75°F)
Heating : Indoor
: D.B. 20°C (68°F)
Refrigerant piping length (one way) : Main Piping (From outdoor unit to branch box) : 5m
2. Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
3. Guaranteed voltage
MXZ-8B140/160VA: 198~264V, 50Hz
MXZ-8B140/160YA: 342~456V, 50Hz
4. Above data are based on the indicated voltage.
MXZ-8B140/160VA: Single, 50Hz, 220/230/240V
MXZ-8B140/160YA: 3-phase, 50Hz, 380/400/415V
5. Refer to the service manual of indoor unit for the indoor unit's specifications.
OCH480D
MXZ-8B140VA
kW
kW
*1
A
17.62/16.85/16.15
*1
%
A
kW
kW
*1
17.68/16.91/16.21
A
*1
%
A
A
kW
W
kW
K/min (CFM)
dB
Cooling
dB
Heating
W
mm (in.)
D
mm (in.)
H
mm (in.)
kg (lbs)
kg (lbs)
L
Liquid
mm
Gas
mm
Indoor side
Outdoor side
[15.88mm
[19.05mm
5/8 inch
3/4 inch
Branch Piping (From branch box to each indoor units) : each 3m
Indoor
P-series
M-series, S-series
D.B. 35°C, W.B. 22.5°C
D.B. 32°C, W.B. 23°C
D.B. 19°C, W.B. 15°C
D.B. 21°C, W.B. 15°C
D.B. 28°C
D.B. 27°C
D.B. 17°C
D.B. 20°C
MXZ-8B160VA
14.0
15.5
3.86
4.71
21.63/20.69/19.82
99.6
99.0
14
16.0
18.0
3.87
4.77
21.90/20.95/20.08
99.5
99.0
14
Please refer to "9.ELECTRICAL WIRING"
29.5
Single, 50Hz, 220/230/240V
Munsall 3Y 7.8/1.1
Linear Expansion Valve (In branch box)
ANB33FDSMT
2.9
3.3
HP switch, LP switch, Discharge thermo
Propeller fan × 2
100(3,530)
106(3,742)
50
51
52
54
330+30(13+1-3/16)
129(284)
Outdoor : D.B. 7°C (45°F), W.B. 6°C (43°F)
Outdoor
D.B. 46°C
D.B. –5°C
D.B. 21°C, W.B. 15°C
D.B. –15°C, W.B. –15°C
12
kcal/h = kW o 860
Conversion formula:
Btu/h = kW o 3412
CFM
MXZ-8B140YA
MXZ-8B160YA
14.0
3.86
5.93/5.63/5.43
98.9
7
16.0
3.87
5.95/5.65/5.44
98.9
7
13
3-phase, 50Hz, 380/400/415V
Hermetic
ANB33FNBMT
2.9
Line start
-
Plate fin coil
0.060+0.060
100(3,530)
Reverse cycle
50
52
950(37-3/8)
1,350(53-1/8)
139(306)
R410A
8.5(18.7),40m
2.3(FV50S)
[9.52
[15.88
Flared
Flared
= m
/min o 35.31
3
15.5
4.71
7.24/6.87/6.63
98.9
18.0
4.77
7.32/6.95/6.70
99.0
3.3
106(3,742)
51
54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxz-8b160yaMxz-8b160vaMxz-8b140ya

Table of Contents