SAFETY INSTRUCTIONS

Installation, commissioning and servicing must only be carried out by qualified personnel in compliance with
national and local regulations in force in the country of installation.
Warning
The manufacturer assumes no liability resulting from failure to follow the instructions in this booklet.

INSTALLATION

Location of installation

Technical data, dimensions, and connections are provided in the Appendix.
The appliance must be installed at least 300mm from any potential side walls, 500mm between the
working surface and any ceilings and 100mm from any potential back walls.
Remove the two transportation screws from the rear of the unit.
Ensure all vents are unobstructed.
If the appliance must be fitted near walls, partitions, kitchen furniture, decorative elements etc, we
recommend they are made from non-inflammable material; otherwise they should be covered with a
suitable heat resistant material. We recommend full attention is paid to fire regulations.
Install this appliance beneath an extraction canopy.

Assembly

Before connecting the appliance, all protective covers must be removed. Clean the work area and
external parts carefully with a solvent to remove any traces of glue.
Check with a spirit level. Levelling can be achieved by adjusting the legs.
Connecting appliances (Fig 1)
Place the appliances together and adjust them to the same level using the adjustable feet.
Connect the appliances using the holes situated on the side at the front and back of the hob.
Fig 1

Connecting to an electricity supply

Before connecting the appliance, check that the mains voltage corresponds to the value shown on the
data plate.
The appliance must be powered by a separate electric cable which is properly specified (see Table T1)
The cable type should be at least H 07 RN-F.
Fixed wiring insulation must be protected by insulated sleeving having a temperature rating of at least 60
Deg C.
Ensure plug/socket is accessible at all times.
Connect the cable to the terminal board following the instructions on the electrical diagrams on the
appliance.
Terminal block is found behind the control panel.
When using a 3 Phase power supply removal of the terminal link between 1 and 2 is required.
Ensure the earth cable is longer than the other cables, so that in the event that the cable clamp breaks, it
is the last lead to disconnect.
For a direct connection to a power supply, a device which guarantees disconnection from the power
supply is required, with a minimum contact separation of 3mm to ensure complete disconnection in case
of overvoltage in category III, in compliance with installation instructions.
Earth and equipotential connection
The appliance must be connected to an equipotential system – the terminal is situated near the entry point
of the electrical supply cable and is marked by the symbol
The appliance must be earthed. Connect the earth cable to the terminal near the terminal block marked
by the symbol