Advertisement

Read All Instructions Care-
fully Before Starting The In-
stallation or Operating This
Heater.
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE
YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
S
U
NorthlineExpress.com
Owners Manual
Owners Manual
Owners Manual
Owners Manual
Owners Manual
Logwood 2421
CAUTION!
SAVE THIS MANUAL FOR FUTURE REFERENCE
UNITED STATES STOVE COMPANY
C
S
www.NorthlineExpress.com
EPA EXEMPT PER
METHOD 28A
TESTED TO
UL 1482
DO NOT USE THIS HEATER
IN A MOBILE HOME OR TRAILER
227 Industrial Park Road
P.O. Box 151
South Pittsburg, TN 37380
(423) 837-2100
851094D
Toll-Free 1-866-667-8454

Advertisement

Table of Contents
loading

Summary of Contents for US Stove Company Logwood 2421

  • Page 1 Owners Manual Owners Manual Owners Manual Owners Manual Owners Manual Logwood 2421 EPA EXEMPT PER METHOD 28A TESTED TO UL 1482 CAUTION! Read All Instructions Care- fully Before Starting The In- stallation or Operating This DO NOT USE THIS HEATER Heater.
  • Page 2: Tools And Materials Needed

    CONGRATULATIONS! You've purchased a heater from North America's oldest manufacturer of wood burning products. By heating with wood you're helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree each year. Future generations will thank you. Tools and Materials Needed MATERIALS TOOLS...
  • Page 3: Safety Rules

    Safety Rules SAFETY NOTICE: If this heater is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read these rules and the instructions carefully. Check with local codes.
  • Page 4: Installation

    MINIMUM CLEARANCE Installation TO COMBUSTIBLE WALLS Place the heater on solid masonry or solid concrete. When the heater is used on a combustible floor, use an Underwrit- ers Listed floor protector. The floor protector must comply 18" with UL Standards.The base should extend at least 16" 458mm beyond the door of the heater and should extend under the flue pipe if it is elbowed towards a wall...
  • Page 5: Chimney Connection

    Operation of the Heater FLUE CONNECTION-NON-COMBUSTIBLE WALL BE SURE TO PUT A LAYER OF SAND OR FIREBRICK APPROXIMATELY 1 1/2" THICK IN THE BOTTOM OF THE NON-COMBUSTIBLE WALL STOVE BEFORE STARTING FIRE. Burn wood or wood products only. The wood should be air THIMBLE dried for at least six months prior to use for maximum effi- COLLAR...
  • Page 6 CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall.
  • Page 7 PART A, FIGURE 8 MINIMUM CHIMNEY CLEARANCE TO (FIGURE 5 CONTIUED ON NEXT PAGE) BRICK AND COMBUSTIBLES IS 2 IN. MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND CHINEY CONNECTOR TO HEATER FIRE CLAY LINER MINIMUM 12 IN. (5/8" MIN. WALL THICKNESS) TO COMBUSTIBLES MASONRY CHIMNEY CONSTRUCTED TO...
  • Page 8 PART B MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN. FIGURE 8 - (FIGURE 8 CONTINUED) FACTORY-BUILT MINIMUM CLEARANCE CHIMNEY LENGHT 9 IN. ALL AROUND NONSOLUBLE CHIMNEY CONNECTOR REFACTORY TO HEATER CEMENT CHIMNEY LENGHT FLUSH WITH INSIDE USE CHIMNEY MFRS.
  • Page 9: Service Hints

    WARNING! CAUTION! NEVER STORE FLAMMABLE LIQUIDS, NEVER USE GASOLINE, GASOLINE-TYPE ESPECIALLY GASOLINE. IN THE LANTERN FUEL, KEROSENE, CHARCOAL VICINITY OF THE HEATER. LIGHTER FLUID, OR FLAMMABLE LIQUIDS TO START OR "FRESHEN UP" A FIRE IN THE HEATER. CAUTION! OVERFIRING THE APPLIANCE MAY CAUSE A HOUSE FIRE.
  • Page 10 Model 2421 Repair Parts PART NO. DESCRIPTION QNTY. 40319 REAR LEG 40319 FRONT LEG 40320 MAIN BOTTOM 40321 MAIN SIDE 40322 MAIN BACK 40323 HEARTH PLATE 40324 SLIDING DRAFT PLATE 40325 DOOR FRAME 40326 DOOR 40327 MAIN TOP 40329 40330 LID SUPPORT 40331 LID LIFTER...
  • Page 11 NOTES www.NorthlineExpress.com NorthlineExpress.com Toll-Free 1-866-667-8454...
  • Page 12: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE BACK OF THE HEATER.

Table of Contents