LockState LS-S100 User Manual

LockState LS-S100 User Manual

Standalone keypad access control

Advertisement

LS-S100 LS-N100
Standalone Keypad Access Control
User Manual
Please read the manual carefully before use this unit

Advertisement

Table of Contents
loading

Summary of Contents for LockState LS-S100

  • Page 1 LS-S100 LS-N100 Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit...
  • Page 2: Packing List

    1. Packing List Name Quantity Remarks Keypad User manual Φ20mm×60mm,Special for keypad Screw driver Φ6mm×30 mm Rubber plug , used for fixing Φ4mm×28 mm Self tapping screws , used for fixing Φ3mm×6mm, used for fixing Star screws Please ensure that all the above contents are correct. If any are missing please notify the supplier of the unit.
  • Page 3 programming mode To unlock the door for a PIN user Enter the PIN then press # To unlock the door for a card user Present the card 3. Description The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader.
  • Page 4: Specifications

    5. Specifications ±10% Operating Voltage DC 12V User Capacity 2000 Card Reading Distance 3-6 cm <60mA Active Current Idle Current 25±5 mA Lock Output Load Max 3A Alarm Output Load Max 20A Operating Temperature -45℃~60℃ Operating Humidity 10%- 90% RH Waterproof Conforms to IP68 Adjustable Door Relay time...
  • Page 5 7. Wiring Colour Function Description Pink BELL_A Doorbell button one end Pale blue BELL_B Doorbell button to the other end Green WG output D0 White WG output D1 Grey ALARM Alarm negative(alarm positive connected 12 V+) Yellow OPEN Exit button one end(the other end connected GND) Brown D_IN Magnetic switch one end(the other end connected GND)
  • Page 6: Sound And Light Indication

    Electric Strike and Fail-Secure wiring diagram: 8. To Reset to Factory Default a. Disconnect power from the unit b. Press and hold # key whilst powering the unit back up c. On hearing two “Di” release # key, system is now back factory settings Please note only installer data is restored, user data will not be affected 9.
  • Page 7: Detailed Programming Guide

    Operation failed DiDiDi Enter into programming mode Bright In the programming mode Bright Exit from the programming Bright mode Open the door Bright Alarm Bright Alarm 11. Detailed Programming Guide Master code # 11.1 User Settings 999999 is the default factory master code To enter the programming mode To exit from the programming mode Note that to undertake the following programming the master user must be logged in...
  • Page 8 programming mode) To add a card user (Method 1) Read card This is the fastest way to enter cards, Cards can be added continuously without exiting user ID number auto generation. programming mode To add a card user (Method 2) ID number Read card This is the alternative way to enter cards...
  • Page 9 To change a PIN in card and PIN mode Read Card Old PIN # New PIN # New PIN # (Method 1) Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode ID number # Old PIN # New PIN #...
  • Page 10 11.2 Door Settings Relay Output Delay Time To set door relay strike time Master code # 0~99 0-99 is to set the door relay time 0-99 seconds Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically.
  • Page 11 12.The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input.

This manual is also suitable for:

Ls-n100

Table of Contents