INSTALLATION INSTRUCTIONS
Connecting electric dryer(cont.)
USA only
WARNING
Four-Wire connection for electric dryers: Direct wire
ends of the three shorter wires into a hook shape.
the dryer. Install a UL-listed strain relief into the power cord
through the strain relief.
UL-Listed
Cord
Ground Wire
Terminal
UL-Listed
Strain Relief
cable.
reinstallation of the dryer.
screw to the center screw of the terminal block. Attach the two
hot leads of the power cable to the outer terminal block screws.
Attach the white neutral wire to the center terminal block
screw. Attach the power cable ground wire to the green ground
screw.
block access cover.
Hot
Neutral
Ground
Screw
Power Cord
Ground Wire
conductor
. Reinstall the terminal