Connecting electric dryer(cont.)
USA only
WARNING
Four-Wire connection for electric dryers:
Power cord
the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed,
conductor power cord through the
strain relief.
UL-Listed
Cord
Terminal
UL-Listed
Strain Relief
INSTALLATION INSTRUCTIONS
conductor and closed loop or forked
terminals with upturned ends.
screw to the center screw of the terminal block. Attach the two
hot leads of the power cord to the outer terminal block screws.
Attach the white neutral wire to the center terminal block
screw. Attach the power cord ground wire to the green ground
screw.
block access cover.
Hot
Neutral
Ground
Screw
Power Cord
Ground Wire