Sanyo PLC-UF15 Service Manual page 32

Multimedia projector
Hide thumbs Also See for PLC-UF15:
Table of Contents

Advertisement

* NO POWER-2
Check the switching regulator.
STR-Z2156
Switching regulator
Caution : "HOT" Circuit !
If a temperature of this
frame reaches to 150˚C,
the IC632 will be shut
down.
IC632
7
11
Timing chart
Pin 4
OSC OUT
Pin 2
Pin 10
Troubleshooting
If this Vcc voltage reaches to
abnormal voltage (exceeds
22V), the IC632 will be shut
down.
Vcc
8
PROTECTION
ABNORMAL
ABNORMAL
START
TEMP. DET.
VOL. DET.
DELAY
LATCH
REF
OSC
OC-RC
OSC
CONTROL
6
5
4
CONT
CHECK !
Check the signal at pin 5
of T621. (Switching power
IC output signal.)
G (H)
9
15
2
Vin
1
FET
OUT
14
LOGIC
FET
12
10
G (L)
VOLTAGE CONTROL
ABNORMAL VOLTAGE DETECT
-32-
T621
D655
D651
5
D652
6
1
5
2
PC611
4
3
6
1
PC612
5
2
4
3
If this voltage reaches to
abnormal voltage (exceeds
6.8V), the IC632 will be shut
down.
9V
16V
6.25V
-6V
3
3
2
2
IC652
1
1
<FF>

Advertisement

Table of Contents
loading

Table of Contents