NOTE:
THIS REPLACEMENT IS ONLY FOR THE J, B, AND G-SERIES ICE MACHINES.
COMPONENT CHANGES VARY WITH THE TYPE OF MACHINE. FOR J-SERIES MACHINES ONLY, THE
RUN CAPACITOR NEEDS TO BE REPLACED WITH THE ONE INCLUDED IN THE KIT. B AND G-SERIES
MACHINES NEED ALL OF THE START AND RUN COMPONENTS REPLACED WITH THE ONES
INCLUDED IN THE KIT.
1. Disconnect power to the ice machine at the electrical
disconnect (moving the toggle switch to the off
position will not disconnect line voltage).
2. Remove panels (top, front, left and right sides).
3. Recover refrigerant from ice machine.
4. Remove right side corner post (when facing the front
of the machine) and back panel.
5. Remove wiring from compressor terminals.
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879
Web Site -
www.manitowocice.com
J/B/G-0600 COMPRESSOR REPLACEMENT
Installation Instructions
6. Unsweat suction line at compressor port. Unsweat
discharge and process lines at the T fitting and
swage joint (or after "T" fitting, if remote)
respectively.
NOTE:
IF
REPLACING
REMOTE ICE MACHINE, BE SURE TO
UNSWEAT THE CONNECTION BETWEEN
THE HPR VALVE AND THE PROCESS
TUBING AT THE "T" FITTING.
Swage Joint
"T" Fitting
7. Remove compressor from machine. Make sure to
crimp and braze shut ports to compressor.
8. Insert new compressor into the machine, as shown.
START AND RUN
COMPRESSOR
IN
A
8006183
Sheet 1 of 3
06/25/01