Power Supply
Controls
Input connections
Output connections
Loop output
Loop cable
Indicators
Sarabec Ltd declares that the LA240 complies with all relevant EU directives. The
full EU declaration of conformance for the LA240 is available from Sarabec Ltd.

Specifications

• 18V 1.5A Power Supply
• 12-24V DC 2A External Supply
• Rotary Volume Control
• Rotary Tone control
• On/Off power switch
• Source selector switches
• Priority switch
• Digital Audio TOSlink/Coaxial
• 2 x Microphone inputs. 3.5mm mono jack plug. DC powered 5V
for electret microphones
• 2x Aux In Left/Right line inputs. Phono/RCA sockets. For direct
connection to a TV sound output or other audio source via SCART
or other suitable socket.
• Push grip connectors for loop cable or loop pad (Labelled: Loop
Cable). Loop will give full output with loop resistance between 0.5
and 1.5 Ohms.
• 3.5mm stereo jack for headphones (Phones) 8-60 Ohms
• 3.0A output current @ 100-5KHz. Meets BS EN60118-4:2006 for
a loop not exceeding 6.5m (20ft) in width . Suitable for areas up
to 70m
2
• Single turn loop cable. System supplied with 40m (130ft)
24/0.2mm (0.75mm
length 11m = 0.5 Ohms
• Blue/Red LEDs
) single core PVC insulated cable. Min cable
2
11