17. Airflow control
17.1. VERTICAL AIR FLOW DIRCTION
1) Press the SWING button (
The vertical air flow louvre will swing.
2) Press the SWING button (
vre is at the desired position.
The adjusted position will be memorized and will be automati-
cally set to the same position when operated the next time.
17.2. HORIZONTAL AIR FLOW DIRCTION
1) Press the SWING button (
The horizontal air flow louvre will swing.
2) Press the SWING button (
louvre is at the desired position.
The adjusted position will be memorized and will be automati-
cally set to the same position when operated the next time.
CAUTION: Never attempt to adjust the louvres manually.
Manual adjustment of the louvres can cause the unit to malfunc-
tion.
When the vertical air flow louvre is positioned at the lowest posi-
tion in the COOL or DRY mode for an extended period of time,
condensation may result.
CAUTION: Never attempt to adjust the louvres manually.
Manual air flow on the louvres can cause the unit to malfunction.
Position in the COOL or DRY mode for an extended period of time,
When the air flow air flow louvre is positioned at the lowest conden-
sation may result.
18. COANDA AIR FLOW
Press the COANDA AIR FLOW button during cooling or dry operation
when you do not want to feel cold air.
Vertical air flow louvre is set obliquely upward to deliver cool air to the
ceiling.
Press the button during heating operation. Vertical air flow louvre is set
downward to deliver the warm air down to the floor and warm you.
During operation, press the COANDA AIR FLOW button.
The remote control will display "
TO CANCEL
Press the COANDA AIR FLOW button again.
NOTE: •
The COANDA AIR FLOW setting is cancelled When you
press FULL POWER button while COANDA AIR FLOW is
set.
If you want AIR FLOW operation in FULL POWER mode,
press COANDA AIR FLOW button during FULL POWER
operation.
19. Difference relating to set temperature
Manual mode
Cooling
Heating
Can be changed
Can be changed
between 18°C and
between 18°C and
32°C using remote
32°C using remote
control.
control.
) on the remote control once.
) again when the vertical air flow lou-
) on the remote control once.
) again when the horizontal air flow
"
Dehumidifying
Automatic setting.
Can be changed
within ±2°C.
20. Dehumidifying operation control
If the room temperature is 26°C or higher when dehumidifying opera-
tion starts, the dehumidifying operation provides a low cooling effect in
accordance with the room temperature setting automatically deter-
mined based on the outside air operation. (The setting value is the
same as the set temperature for cooling operation in the auto mode.)
If the room temperature is lower than 26°C when dehumidifying opera-
tion starts, the dehumidifying operation minimizes the lowering of the
room temperature.

21. FULL POWER Operation

In this operation, the air conditioner works at the maximum power to
make the room cool or warm rapidly.
During operation, press the FULL POWER button.
The remote control will display "
The temperature display will go off.
The green FULL POWER lamp on.
The unit will light up.
TO CANCEL
Press the FULL POWER button again.
The FULL POWER operation will also be cancelled when the oper-
ation mode is changed, or when the unit is turned off.
The green FULL POWER lamp on the unit will turn off.
NOTE: •
The air conditioner will operate at "Extra HIGH" fan speed
for 5 minutes, and then shift to "HIGH" fan speed.
You can not set the temperature or fan speed during the
FULL POWER operation.
To turn off the FULL POWER lamp, press the DISPLAY
button.

22. Self Clean operation

Heating or Fan operation and Plasmacluster operation are performed
simultaneously.
The judgment of whether Heating or Fan operation is used is based on
the outside air temperature at 3 minutes after the start of internal
cleaning. But the multi use of AYXPC18LR is only Fan operation.
The operation stops after 40 minutes.
• During this operation the vertical air flow louver moves and stays two
positions.
It turns to the lower direction and stays for 30 minutes.
Next moves upward and stays for 10 minutes.
Heating operation
23. Plasmacluster Ion function
Plasmacluster Ions released into the room will reduce some airborne
mold.
Press the PLASMACLUSTER button during operation,
The Plasmacluster function is operated together with the air condi-
tioner operation.
Press the PLASMACLUSTER button when the unit is not operating.
The Plasmacluster function is operated in fan only mode. The
mode symbol of remote control will go off and the fan speed cannot
be set to AUTO.
NOTE: Use of the PLASMACLUSTE operation will be memorized,
and it will be activated the next time you turn on the unit.