Turn on Electrical
Power and Open Main Shutoff
Gas Valve
Check the Igniters
Operation of electric igniters should be checked
after the appliance and supply line connectors have
been carefully checked for leaks and the appliance
has been connected to electric power. To check for
proper lighting:
a.
Push in and turn a surface burner knob to the
LITE position. All electronic surface ignitors
will spark at the same time. However, only the
burner you are turning on will ignite.
b.
The surface burner should light once the flow
of gas reached the surface burner. Each burner
should light within four (4) seconds in normal
operation after air has been purged from supply
lines. Visually check that burner has lit.
c.
Once the burner lights, the control knob should
be rotated out of the LITE position.
There are separate ignition devices for each burner.
Try each knob separately until all burner valves have
been checked.
5. Adjust
the "LOW" Setting of the Dual (Bridge)
Surface Burner Valve (Figure 16):
Note: On the dual valve the low setting of each portion
(rear portion of bridge burner and the center portion of
bridge burner) should be adjusted individually.
a. Push in and turn control to LITE until the rear portion
of the bridge burner ignites only.
b,
C.
d.
e.
Quickly
turn knob to LOWEST POSITION.
If burner goes out, reset control to OFF.
Remove the surface burner control knob.
The rear portion of the bridge burner flame size
can be increased or decreased by turning screw A
(see Figure 16). Use screw B to adjust the flame
size of the center portion of the bridge burner. Turn
counterclockwise
the screw to increase flame size.
Turn clockwise the screw to decrease flame size.
Adjust flame until you can quickly turn knob from
LITEto LOWEST POSITION without
extinguishing the
flame. Flame should be as small as possible without
going out.
Note: Air mixture adjustment is not required on surface
burners.
4. Adjust
the "LOW" Setting of Regular Surface
Burner Valves (Figure 15):
a. Push in and turn control to LITE until burner ignites.
b. Quickly
turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. Insert a thin-bladed
screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame
size can be increased or decreased by turning the
screw. Turn counterclockwise
to increase flame size.
Turn clockwise to decrease flame size. Adjust flame
until you can quickly turn knob from LITE to LOWEST
POSITION without extinguishing the flame. Flame
should be as small as possible without going out.
Note: Air mixture adjustment is not required on surface
burners.
Figure 16
When All Hookups
are Complete
Make sure all controls are left in the OFF position.
Model
and
Serial
Number
Location
The serial plate is located under the cooktop burner box.
When ordering parts for or making inquires about your
oven, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
on your oven.
Figure 15
Before
You Call for Service
Read the Before You Call for Service Checklist and
operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes
common occurrences that are not the result of defective
workmanship or materials in this appliance.
Refer to your Use and Care Guide for Sears service
phone numbers, or call 1-800-4-MY-HOME
®