Wall Outlet
Location
4"
(10_ cm).-.4_
(12.7 cm)
on rear wall.
__
16"
CENTRE(40.6 cm)
LINE
OF UNIT
NOTE: If an outlet
I
is not available,
have one installed
I
by a qualified
_._
technician._,,
..
_
CENTRE
LINE
"_Ngure4
OFUNIT
Provide
an Adequate
Gas Supply
This cooktop is designed to operate on natural gas at 4"
(10.2 cm) of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation,
the maximum inlet pressure to
the regulator must be no more than 14" (35.6 cm) of
water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1 "(2.5 cm) (or 2.5 kPa) greater than the regulator
manifold pressure setting. The regulator is set for 4"
(10.2 cm) of manifold pressure, the inlet pressure must
be at least 5" (12.7 cm).
The gas supply line to the appliance should be 1/2" (1.3
cm) or 3/4" (1.9 cm) pipe.
LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LP gas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANEGAS
CONVERSION".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and
all local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Important:
Remove all packing material and literature
from cooktop before connecting gas and electrical
supply to cooktop.
Install
Pressure
Regulator
Install the pressure regulator with the arrow on the
regulator pointing up toward the unit in a position
where you can reach the access cap.
_J__
Do not make the connection too
tight. The regulator is die cast. Overtightening
may crack
the regulator resulting in a gas leak and possible fire or
explosion.
GAS FLOW
Manual
--_
Pressure
Shutoff
Flare
Flare
Regulator
Valve
Union
Union
Flexible Connector
off
All connections must be wrench-tightened
Figure 5
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the followinc
order:
1. manual shutoff valve
2. 1/2" (1.3 cm) nipple
3. 1/2" (1.3 cm) flare union adapter
4. flexible connector
5. 1/2" (1.3 cm) flare union adapter
6. 1/2" (1.3 cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.
The supply line should be equipped with an approved
shutoff valve. This valve should be located in the same
room as the cooktop and should be in a location that
allows ease of
opening and
closing. Do not
block access to
the shutoff valve.
The valve is for
turning on or
shutting off gas
to the appliance.
Open position
Figure 6

Advertisement

loading