8. CLEANING AND MAINTENANCE OF THE UNIT
1. Remember that you must clean the unit regularly to remove dust from
the surface of heating sections. Dust and dirt on the unit's surface have
a negative effect on the unit's operational efficiency, in some cases a
smell of burning dust can cause a headache and nausea, as well as other
negative health effects. Also a dirty unit cannot operate 100% effectively,
temperature parameters of the room heating can be disrupted.
2. Prior to preventive cleaning of the unit, you must switch off the unit,
unplug it from electric mains (see «Important precautions») and let the unit
cool down.
3. Clean the unit's sections and other surfaces with a soft, slightly damp
duster/cloth. The cloth must not leave fluff on the unit's surface.
4. It is not recommended to use detergents, including materials containing
abrasive elements.
5. During cleaning, please, do not damage the unit's surface by sharp
objects (hard sponge, polishing paper, etc). Scratches on the painted
surface can result in rusting.
Switch on and use the unit again only having carried out all «Important
precautions»; also make sure that the unit's surface is absolutely dry.
9. TROUBLESHOOTING
Possible malfunctions and remedies for them:
Malfunction
Cause
1. The heating element is faulty
1. The heater heats poorly
2. Low voltage in the electric mains
1. No voltage in the electric mains
2. Breakdown of the electric cable
2. The heater does not work
3. The automatic circuit breaker of the
electric mains is faulty
4. Breakdown in the heating element circuit
If you are not able to remedy a malfunction according to the
recommendations or other malfunctions occur, contact the authorized
service center of Timberk.
Temperature
requirements*
Humidity
requirements*
We are exploring new technologies and we constantly improving the quality
of our products. That's why specifications, design and accessories are
subject to change without any specific notice.
* This product must have storage in dry, well-ventilated space of warehouse at the temperature
not lower than -30°
After end of life the fan heater should be utilized in accordance with the
norms, regulations and procedures effective in the place of utilization. For
more detailed information please contact representatives of local authorities.
Remedy
1. Contact the authorized service center
of Timberk
2. Check voltage in the electric mains
1. Check presence of voltage in the
electric mains
2. Check integrity of the electric cable and
replace it if necessary
3. Check operability of the automatic circuit
breaker of the electric mains and replace
the faulty circuit breaker if necessary
4. Contact the authorized service center
of Timberk
10. TRANSPORTATIOM AND STORAGE
Transportation and
storage
11. UTILIZATION
www.timberk.com • electric oil filled radiator
From -30° to +50°
From 15% to 85%
(without a condensate)
7