ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
GROUNDING
INSTRUCTIONS
•The operating voltage (Volts),Amperage (Amps) and
Frequency (Hz)of this dryer are indicated on the Rating
Plate located to the right of the loading port.
• Connect this dryer to a circuit corresponding to that
indicated on Rating Plate and protected by fuses or a
circuit breaker in accordance with local codes.
• Use a power supply cord kit marked for use with clothes
dryer. For 208V and 240V models, use a power supply cord
kit marked for use with clothes dryers.
I
O NOT USEEXTENSIONCORDWITH THIS APPLIANCE
For alternate 208V or 240V power supply hook-up, proceed
as follows:
• Remove rear access panel.
• Connect supply wire leads to terminal block as shown on
sketch below, depending on type of installation.
• Make sure screws on terminal block are tight.
I
This appliance must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electrical current.
WARN ING:
Improper connection of the
equipment grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman if you
are in doubt as to whether the appliance is properly grounded.
Do not modify the plug providedwith the appliance -if it will not fit
the outlet, have a proper outlet installedby a qualified electrician.
, WARNING:
Appliance grounded to neutral
conductor through a link. If used in a mobile home, a new
construction, a recreational vehicle or if local codes do not
permit grounding through neutral, a 4-conductor cord or cable
assembly for use with clothes dryers must be used with the
following specifications: Type St. Cable, 125/250 Min. Volt,
30 Amp with closed-loop terminals and secured with a UL
recognized strain relief. See manufacturer's instructions.
FOR THREE-WIRE
SUPPLY
(208V & 240V MODELS)
• Connect two (2) HOT lines to outer screws (L1 and L2) of
terminal block.
• Connect Neutral line to center screw (N) of terminal block.
REAR
HOT WIRE \
GREEN
HOT WIRE
GROUNDING
WHITE
SCREW
_ NEUTRAL
GROUND
WIRE
STRAP
POWER SUPPLY CORD 3#10
_-
AWG MINIMUM COPPER
CONDUCTORS 30
AMP, 240V, WITH
TYPE UL RECOGNIZED
MINIMUM RATED 90°C
208 OR 240
VOLTOPERATION
N
L 2
120/208 OR 120/240
2o8v o r 24ov I
VOLTSUPPLY
_f
FRONT
_
I
(USE ONLY
30 AMP FUSES)
INSIDE TOP VIEW OF DRYER
FOR PERSONAL SAFETY, THISAPPLIANCE MUST BE
I
PROPERLY GROUNDED.
I
• Properly strain relief the cordset or cable to the cable entry
hole with UL recoqnized strain relief.
• Make sure cordset or the cable is away from the rotating
drum.
• Replace access panel.
3 WIRE RECEPTACLE
(10-30R)
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
FOR FOUR-WIRE SUPPLY
{208V & 240V MODELS}
• Remove ground strap and discard. Re-screw green
grounding screw in place.
• Connect two (2) HOT lines to outer screws (L1 and L2) of
terminal block.
• Connect Neutral line to center screw (N)of terminal block.
• Attach ground wire of power supply to green grounding
screw beside terminal block.
GREEN
/
WHITE
GROUNDING .___:
_
WHITE
II
v
I1\\
JNEUTRAL
SCREWf//
/_
WIRE
OTW'REII¢IIOII : II
OI1 11
LIt
N
L21
_, 208V or240V _.
"_
FRONT
p POWER SUPPLYCORD
/4#10 AWG MINIMUM
COPPERCONDUCTORS, 30
AMP, 240V, WITH CLOSED-
LOOP TERMINALS TYPE UL
RECOGNIZED MINIMUM
RATED90°C.
REMOVE GROUND STRAP
ANDDISCARD 208OR240
VOLT OPERATION
120/208 OR
120/240 VOLT SUPPLY (USE
ONLY 30AMPFUSES)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Properly strain relief the cordset or cable to the cable
entry hole with UL recoqnized strain relief.
• Make sure cordset or the cable is away from the rotating
drum. Replace access panel.
4-WIRE RECEPTACLE (14-30R)
Typical 30 amp receptacle for use
where local codes permit use of
flexible type power supply cord
(pigtail).
4-CONDUCTOR CORD
ASSEMBLY ( Type ST Cable)
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through neutral.
2