REMOTE PANEL - MODEL NO. 900-RC
An optional wired Remote Panel Model No. 900-RC (15) can be ordered. It comes with 10
metres of flat ribbon cable (14) that has 8 position modular male connector on either end.
The Remote Panel (15) can be used to switch on / switch off the charger and also monitor the
charging status of the charger from a remote location.
CONTROLS AND INDICATIONS
The Remote Panel has the following controls / indications:
Keypad switch for switching on and switching off
Red LED under "I Phase"
Yellow LED under "Uo Phase" *
Green LED under "U Phase"
Green LED under "Power"
* Note: When " Loaded Battery" application is selected (see pages 16 & 17), this will
indicate the Float stage ("U" Phase) as in this application, the Boost stage
voltage ("Uo" Phase) is the same as the Float stage voltage ("U" Phase).
CONNECTION
To connect the Remote Panel to the charger, insert one connector of the flat ribbon cable (14)
into the modular jack on the Remote Panel (15) and the other connector to the modular jack
(6) on the charger.
OPERATION
The charger should be first switched on with the help of the AC input power on / off switch
(9) located on rear panel of the charger.
The charger can now be switched on and off with the help of the keypad switch on the

Remote Panel (15).

INDICATIONS
Whenever the charger is switched on, the Green LED "Power" will be lighted. The other
LEDs indicate the charging status as follows:
Red LED "I Phase" is lighted – Indicates that charger is in Stage 1 - Constant
Current, Bulk Charge Mode ("I" Phase) and is delivering 45 A to 36 A (SEC-
1245A) or 25 A to 20 A (SEC-2425A)
Yellow LED "Uo Phase" is lighted – Indicates that the charger is in Stage 2 –
Constant Overcharge Voltage, Timed Absorption / Boost Charge Stage ("Uo"
Phase) and is delivering between 36 A to 4.5 A (SEC-1245A) or between 20 A to
2.5 A (SEC-2425A)
Green LED "U Phase" is lighted – Indicates that the charger is in Stage 3 -
Constant Voltage, Float or Maintenance Charge Mode ("U" Phase). The charger is
delivering < 4.5 A (SEC-1245A) or < 2.5 A (SEC-2425A). The battery is fully
charged.