Acoustic Data; Acoustic Data - LG LS090HEV1 Engineering Manual

Single zone mega wall mounted
Hide thumbs Also See for LS090HEV1:
Table of Contents

Advertisement

Figure 1: Outdoor Unit Sound Levels
3.28 ft
Figure 2: Sound Pressure Levels for Mega Inverter Outdoor Units.
LSU090HEV1
80
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
1000
2000
4000
Octave Band Center Frequency (Hz)
LSU240HEV1
80
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
1000
2000
4000
Octave Band Center Frequency (Hz)
OUTDOOR UNIT ACOUSTIC DATA
Center of
Outdoor Unit
LSU120HEV1
80
70
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
NC-25
20
Approximate
NC-20
Hearing
Threshold
NC-15
10
8000
63
125
250
500
Octave Band Center Frequency (Hz)
Figure 3: Sound Pressure Levels for Mega 115V Outdoor Units.
80
70
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
NC-25
20
NC-20
Approximate
Hearing
NC-15
Threshold
10
8000
63
125
Octave Band Center Frequency (Hz)
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG " is a registered trademark of LG Corp.
Mega Inverter and Mega 115V Outdoor Units
• Measurements are taken 3.28 ft away from the front of the unit.
• Sound pressure levels are measured in dB(A) with a tolerance of ±3.
• Sound pressure levels are tested in an anechoic chamber under
ISO Standard 3745.
• Sound level will vary depending on a range of factors including the
construction (acoustic absorption coefficient) of a particular room in
which the unit was installed.
Table 7: Outdoor Unit Acoustic Data
Model
Mega Inverter
LSU090HEV1
LSU120HEV1
LSU180HEV1
LSU240HEV1
Mega 115V
LSU090HXV
LSU120HXV
80
70
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
NC-25
20
Approximate
NC-20
Hearing
Threshold
NC-15
10
1000
2000
4000
8000
63
LSU090HXV
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
250
500
1000
2000
4000
8000
Sound Pressure Levels (dB[A])
Cooling (Max)
47
47
51
53
47
47
LSU180HEV1
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
125
250
500
1000
2000
4000
8000
Octave Band Center Frequency (Hz)
LSU120HXV
80
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
1000
2000
4000
8000
Octave Band Center Frequency (Hz)
Heating (Max.)
47
47
51
53
47
47
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
PRODUCT DATA | 23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls120hev1Ls180hev1Ls240hev1Ls090hxvLs120hxv