Ei Electronics Ei 203EN Instruction Manual page 27

Battery powered carbon monoxide alarm
Table of Contents

Advertisement

B15583-R3-203-204-205 U&C 8/5/04 7:45 AM Page 27
Self Diagnostics
Tamperproof
Interconnect
(Ei205CEN only)
CO Alarm Memory:
(Ei205EN
& Ei205CEN only)
End of Life Indication:
Dimensions
Weight
: Horn beep and amber fault light flashes every 40
seconds if a sensor fault is found.
: Locking Rivet(s) supplied.
: Up to 12, Ei205CEN Alarms can be interconnected, so
that when one senses CO, all alarm.
: A unit will indicate if it has been in alarm previously by
flashing the red light for 2 seconds every 40 seconds
(2 flashes for 50 ppm CO, 4 flashes for 100 ppm CO and
8 flashes, for 300 ppm CO). When the test button is
pressed the red light flashes as per table B and also
indicates the previous CO alarm level detected. The
memory is cleared by holding down the test button until
the red light stops flashing.
Amber light flashes every 45 seconds after 6 years to
show the unit must be replaced.
: 135 x 105 x 71 mm.
: 260g.