Westfire WF ONE SERIES Installation Manual And Operating Instructions

Hide thumbs Also See for WF ONE SERIES:

Advertisement

WESTFIRE · WF ONE SERIES
WF ONE SERIES
uk: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
daNSk INgENIøRkuNSt
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WF ONE SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Westfire WF ONE SERIES

  • Page 1 WESTFIRE · WF ONE SERIES WF ONE SERIES uk: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS daNSk INgENIøRkuNSt...
  • Page 2 WESTFIRE · WF ONE SERIES WF ONE SERIES This manual refers to the stove type listed above, which has been tested in accordance with EN13240.
  • Page 3 For further information on installing and using fireplaces and wood burning stoves, please see the relevant building regulations that apply to the country in which WESTFIRE WF ONE SERIES has been approved, as well as the relevant brochure on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep.
  • Page 4: Important Warning

    Minimum draft: WESTFIRE ONE SERIES stove has been tested with a draft of 12 Pa. Maximum draft 25 Pa. Flue gas flow 3.8 g/sec.
  • Page 5 The WESTFIRE WF ONE SERIES is fitted as standard with a closed air supply collar, this enables the stove to take all combustion air (primary, secondary and tertiary) directly from outside with 100mm pipe from the stove.
  • Page 6 WESTFIRE · WF ONE SERIES There are no European rules regarding the minimum distance to non-flammable walls, Westfire recommend leaving a gap of at least 10 cm behind and to sides of stove. FLuE aNd aIR INtakE POSItIONS WEStFIRE WF ONE SERIES...
  • Page 7 Connection to chimney The WESTFIRE ONE SERIES stove is factory set up with a top flue outlet, this can altered to a rear connection by unbolting top collar and rear cover plate and exchanging collar and plate. Care should be taken to ensure an airtight fit when refitting collar and plate.
  • Page 8 At nominal heat output, expect to refuel your stove approximately once an hour. The WESTFIRE ONE SERIES stoves are all equipped with a control valve for secondary air designed to ensure a plentiful supply of oxygen during firing. When lit, the stove will get very hot and due care must therefore be exercised.
  • Page 9: Door Operation

    When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from possible heat. The handle twists right away from the fire. When shutting the door push the door closed and twist left until the handle firmly closes.
  • Page 10: Troubleshooting

    WESTFIRE · WF ONE SERIES tROuBLE SHOOtINg 1. Fire Will Not Burn - check a) the air inlet is not obstructed in any way, b) that chimneys and flueways are clear, c) that a suitable fuel is being used, d) that there is an adequate air supply into the room, e) that an extractor fan is not fitted in the same room as the fire.
  • Page 11: Warning Note

    Warning! Any unauthorised modification of the appliance is forbidden. Only replacement parts recommended by Westfire ApS should be used for repairs. uk IMPORtER EUROSTOvE LIMITED, UNIT S5, MENDIP INDUSTRIAL ESTATE, MENDIP ROAD, ROOKESBRIDGE.
  • Page 12 PLACE. PUSH IN SECURING PINS ON EACH SIDE BAFFLE (2 IN TOTAL) FIT TWO SIDE STEEL GRATE SPACERS FIT FRONT LOG RETAINER BARS WESTFIRE 2010 TømRERvEj 3 | DK-6800 vaRDE | TElEFON +45 7522 5352 | Fax +45 7522 1352 | WWW.WESTFIRE.DK | E-maIl: INFO@WESTFIRE.DK...

This manual is also suitable for:

Wf two series

Table of Contents