To exit the menu:
•
Press the OFF button to exit the KEYLOCK)
menu.
•
Press the OFF button to exit the SET STOVE
menu.
•
To activate or deactivate the BLOCK BUTTONS
function, press the ON and OFF buttons simulta-
neously.
10.4.9 RESET
This resets all operator entries in the SET STOVE-
menu to their factory settings.
Operator settings like the heating power, convection
fan output and room temperature are maintained.
•
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
•
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
•
Press the ON button to get into the menu.
•
Hold the
button down until the message
RESET appears.
•
Press the ON button to arrive at the menu.
The current setting NEIN (NO) will flash.
•
Use the
+
buttons to select YES or NO.
•
Press ON to confirm.
After confirmation of the YES option, the DONE mes-
sage appears.
To exit the menu:
•
Press the OFF button to exit the RESET menu.
•
Press the OFF button to exit the SET STOVE
menu.
10.4.10 ECONOMY
This makes it possible to reduce the maximum power
setting with the Automatic A heating power setting of
5 to 1-4.
•
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
•
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
•
Press the ON button to get into the menu.
•
Hold the
button down until the message
ECONOMY appears.
•
Press the ON button to arrive at the menu.
The current heating power setting will flash.
•
Use the
+
buttons to change the maxi-
mum heating power setting.
+
at the
+
at the
- 26 -
•
Press ON to confirm.
To exit the menu:
•
Press the OFF button to exit the ECONOMY
menu.
•
Press the OFF button to exit the SET STOVE
menu.
11. Display hours of operation
The hours of operation can be displayed in the top
menu level.
•
Press the button
•
Press the button
12. Display operating data
All the current operating data can be retrieved here,
for example the software version, flue gas tempera-
ture, heating power setting, etc.
•
Press the OFF +
•
Use the
+
buttons to select the individual
parameters.
The following parameters are displayed:
-
Unit model – software version
-
Starting time
-
Flue gas temperature
-
Room temperature
-
Room target temperature
-
Pellet temperature
-
RPM of flue gas fan
-
Air speed
-
Heating power level 01=P1/04=P2/08=P3/
-
Screw conveyor (rotating time <8.0")
-
Resistance (ignition element)
13. Remote control
The delivery contents of the unit include a remote
control.
= Display of the hours of
operation so far
= Display the hours of
operation until the next
special service
buttons at the same time.
012=P4/016=P5
a