Viron P320 eVo Installation And Operating Instructions Manual

Viron P320 eVo Installation And Operating Instructions Manual

Pool and spa pumps

Advertisement

Installation   A ND   O PERATING   I NSTRUCTIONS  
 
 
 
 
 
 
                                   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Melbourne:   0 3   8 796   8 600    
Sydney   N th:     0 2   9 853   2 100  
Brisbane:   0 7   3 308   5 400  
28/01/2015
 
 
 
Viron   C artridge   F ilter  
Pool   a nd   S pa   P umps  
 
INSTALLATION   A ND  
OPERATING   I NSTRUCTIONS  
Gold   C oast:   0 7   5 552   2 600    
 
Sydney   S th:   0 2   8 778   9 500    
 
Adelaide:   0 8   8 152   7 600  
 
 
 
 
I  
Viron   P 320   e Vo  
Viron   P 600   e Vo  
Viron   P 320   e Vo  
Viron   P 600   e Vo  
Perth:   0 8   9 350   2 600  
Townsville:   0 7   4 796   0 100    
 
www.astralpool.com.au  
 
 
sales@astralpool.com.au  
INSTALLATION   A ND   O PERATING   I NSTRUCTIONS  
Bolero   N D   C leaner  
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P320 eVo and is the answer not in the manual?

Questions and answers

Summary of Contents for Viron P320 eVo

  • Page 1         Viron   P 320   e Vo   Viron   C artridge   F ilter   Viron   P 600   e Vo     Pool   a nd   S pa   P umps  ...
  • Page 2   SERIOUS  INJURY  OR  DEATH  MAY  OCCUR  IF  THIS  PRODUCT  IS  NOT  USED,  OPERATED  OR  INSTALLED  ACCORDING   TO   T HESE   I NSTRUCTIONS   A ND   R ELEVANT   A USTRALIAN   S TANDARDS.       THIS  ...
  • Page 3   Model   High   Medium   Low   Viron   P 320   E VO   320   l pm   206   l pm   128   l pm   Viron   P 600   E VO  ...
  • Page 4 INSTALLATION   This   a ppliance   m ust   b e   i nstalled   b y   a   t rained   p ool   p rofessional   s ervice   t echnician.     W hen   i nstalling   t he   a ppliance,   e nsure   a ll   parts  ...
  • Page 5 OPERATION   Prime   p ump   i f   h air   a nd   l int   p ot   i s   d ry   a s   f ollows   –   C lose   o ff   v alve   o n   s uction   l ine   i f   p resent.     R emove   l int   p ot   l id.     F ill   lint  ...
  • Page 6 SELECTION   O F   A PPROPRIATE   S PEEDS   General   R ules:     The   t otal   v olume   o f   w ater   i n   y our   p ool   s hould   b e   t urned   o ver   a t   l east   o nce   a   d ay.   •...
  • Page 7 OPERATION   O F   C ONTROL   P ANEL   –   V IRON   P 320   E VO   &   P 600   E VO   The Viron P320 and P600 eVo pumps incorporate an LCD backlit screen with the following features:...
  • Page 8 Using the inbuilt timer to operate pump with an AstralPool Chlorinator or RolaChem dosing unit. Factory Default Setting 1. The inbuilt timers are activated and will control the time the pump operates. 2. Connectivity to AstralPool compliant Salt Chlorinators, RolaChem Chemical dosing controllers or Viron Connect remote Controls is turned “off”. 3. Use the “auto”...
  • Page 9 AstralPool manufactures Salt Chlorinators, RolaChem chemical dosing units or the Viron Connect Touch Screen Control system which can control both the operating times of the all Viron eVo pumps PLUS the speed the pump operates at during each timer period.
  • Page 10 Data cable connector: If a compatible AstralPool VX Salt Chlorinator, Viron Salt Chlorinator or Viron Connect Touch Screen, is connected with the AstralPool communication cable, the speed of the pump and operating hours can be controlled by these devices.  ...
  • Page 11   All   m odel   V iron   e Vo   p umps   a nd   c ompatible   V X   T imer   m odel   c hlorinator   o r   V iron   S alt   C hlorinator •...
  • Page 12   SPEED   S ELECTION   E XAMPLES   F OR   V IRON   P 600   E VO     Function   Speed   Vacuuming   P ool   o r   S pa   Medium   S peed   ( high   s peed   m ay   c ollapse   v acuum   h ose)   Operating  ...
  • Page 13 24 Volt Data (RJ12 Cable)           MAINTENANCE   Maintenance   S chedule:         Y ou   n ew   p roduct   i ncorporates   m oving   p arts   a nd   w ithstands   h igh   v elocity   w ater   w ith   chemicals  ...
  • Page 14 flooding   Three   M onthly   Check   f or   l eaks   f rom   u nderneath   p ump   Call   S ervice   t echnician,   r epair   o r   r eplace   mechanical  ...
  • Page 15 VIRON   E VO   C ONTROL   F LOW   D IAGRAM     Inst.300   V iron   E VO   P ool   &   S pa   P ump   V 01_15  ...
  • Page 16 WARRANTY   AstralPool Australia Pty Ltd (ABN 97 007 284 504) ("AstralPool") provides the following warranty in relation to its Viron eVo series Pool and Spa pumps ("Product"). Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
  • Page 17 Exclusions The warranty will not apply where: the customer is in breach of the Terms and Conditions of Sale; the Product was used for a purpose other than one it was intended for; the Product was repaired, modified or altered by any person other than AstralPool; the Product has not been installed, maintained and/or operated in complete compliance with the installation and operating instructions and any instructions by AstralPool;...
  • Page 18 Astral Pool reserves the right to repair or replace defective components or products at its sole discretion. Astral Pool shall have no liability for incidental or consequential damages or delays caused either directly or indirectly by any malfunction of or defect of or failure of the equipment. Where the equipment is installed in commercial situations including (but not limited to) hotels, motels, caravan parks, health clubs, public pools, body corporate installations, etc the warranty is limited to 12 months.
  • Page 19 Inst.300   V iron   E VO   P ool   &   S pa   P ump   V 01_15  ...
  • Page 20 INSTALLATION   A ND   O PERATING   I NSTRUCTIONS     I   INSTALLATION   A ND   O PERATING   I NSTRUCTIONS   INSTALLATION   A ND   O PERATING   I NSTRUCTIONS     I   INSTALLATION   A ND   O PERATING   I NSTRUCTIONS    ...

This manual is also suitable for:

P600 evo

Table of Contents