Operating Your Heater - HearthRite HR06ML-1 Owner's Operation And Installation Manual

Infrared vent-free propane/lp gas space heater
Table of Contents

Advertisement

Manual Control Models:
HR06ML HR10ML
LIGHTING
INSTRUCTIONS
1.
STOP!
Read
the
information on the side of
heater.
2. Check that gas supply to
heater is on.
3. Push in gas control knob
slightly and turn clockwise
to
the OFF position. ( see
Figures 16 & 17)
4.
Wait five (5) minutes to clear
out any air. Then smell for
gas, including near the floor.
If
you
smell
gas, STOP!
Follow "B"
in
the
information on the side of the
heater. If you do not smell
gas, go to the next step.
5.
Push
in
gas control knob
s l i g h t l y
a n d
counterclockwise
"PILOT/IGN" and depress for
five(5) seconds
NOTE : The first time that the heater
is operated after
connecting the
gas supply , the
control knob
should be depressed for about thirty
(30) seconds. This will allow air to
bleed from the gas system.
6.
With control knob pressed in,
push down and release the
ignitor button. This will light
pilot. If needed, keep pressing
ignitor button until pilot lights.
7. Keep control knob depressed
for ten (10) seconds after
lighting pilot. If pilot goes out,
repeat steps 5,6 and 7.
8. To select the desired heating
level, partially press down the
control knob slightly and rotate
counterclockwise
the downward pressure on the
knob while continuing to turn until
the knob locks at the desired
setting position. Do not operate
between locked positions.

OPERATING YOUR HEATER

TO SELECT
HEATING LEVEL
WARNING: When running
h e a t e r , s e t
O N , L O W o r
safety
positions.(see Figure 19 & 20)
N e v e r
between locked positions. Poor
combustion and higher levels of
carbon monoxide may result.
CAUTION: Do not try to
adjust heating levels by using
the equipment shutoff valve.
Slightly press in control knob and
turn counterclockwise
ON, LOW or HIGH positions(see
Figure 19 & 20).
safety
IMPORTANT: Release downward
pressure while turning control knob.
Control knob will lock at the
desired position.
t u r n
to
Figure 16 - Control Knob In
The OFF Position (HR06ML)
Figure 17 - Control Knob In The
OFF Position (HR10ML)
. Release
Figure 18 - Pilot
c o n t r o l k n o b
a t
H I G H
l o c k e d
s e t
c o n t r o l
k n o b
to the
1 1
HR06ML
Figure 19 - Burner Patterns
HR10ML
Figure 20 - Burner Patterns
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1.
Turn control knob clockwise
to the OFF position.
2.
Turn off all electric power to
the appliance if service is to
be performed.
Shutting Off Burner Only (Pilot
Stays Lit)
Turn control knob clockwise
to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
1.
Remove lower front panel (see
Figure 7 page 7).
2.
Follow steps through 5 under
Lighting Instructions .
3.
With control
knob
strike match. Hold match to
pilot until pilot lights.
4.
Keep control knob pressed in
for 30 seconds after lighting pilot.
After 30 seconds, release control
knob.Follow step 8 under Lighting
Instuctions .
5.
Replace lower front panel.
pressed in,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hr10tl-1Hr10ml-1

Table of Contents