IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should al-
ways be followed to reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before using the heater.
2. The heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. The trim around the heater
outlet becomes hot during heater operation. Keep com-
bustible materials, such as furniture, pillows, bedding, pa-
pers, clothes, and curtains at least 3 ft (0.9 m) from the
front of the unit and keep them away from the sides and
rear.
3. Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the unit is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Discon-
nect power at the service panel and have the heater in-
spected by a reputable electrician before reusing.
5. Do not use outdoors.
6. To disconnect the unit, turn the controls off, and then
switch off at main power supply panel.
7. Do not locate these heaters below any electrical conven-
ience receptacles.
8. Do not install these heaters against combustible, low
density cellulose fibre surfaces.
9. Do not insert or allow foreign objects to enter any venti-
lation or exhaust opening as this may cause an electric
shock or fire, or damage to the heater.
10. To prevent a possible fire, do not block air intake or ex-
haust in any manner.
11. All electrical heaters have hot and arcing or sparking parts
inside. Do not use in areas where gasoline, paint, or flam-
mable liquids are used or stored.
12. Do not modify this heater. Use it only as described in this
manual. Any other use not recommended by the manufac-
turer may cause fire, electric shock or injury to persons.

SAVE THESE INSTRUCTIONS

1.5 in (3.81 cm)
min
6 in (15.24 cm)
1.5 in
(3.81 cm)
min
3 in (7.62 cm)
min
1.5 in (3.81 cm)
3 in (7.62 cm)
min
3 in (7.62 cm)
min
min

Installation Instructions

WARNING: Wiring procedures and connections should
be in accordance with the National Electric Code (NEC &
CEC) and local codes.
WARNING: To reduce the risk of fire, do not store or use
gasoline or other flammable vapors or liquids in the vicinity of
the heater.
CAUTION: High temperature, risk of fire, keep electrical
cords, drapery, furnishings, and other combustibles at least
3 feet (0.9 m) from the front of the heater.
Recommendations for Locating Drapes and Furniture
near Heaters
For most satisfactory operation of the baseboard heaters and
minimum effect on drapes and furniture, the following recom-
mendations should be observed:
1. Hang drapes so that, in use, they extend below the center
line of the heater, but with at least 1.5 inches clearance from
the finished floor covering (such as carpet, if used).
2. Hang drapes so that there is at least 3 inches between the
extreme front of the heater and the nearest fold of the drapes
in the folded back (opened drape) position.
3. Hang drapes so there is at least 1.5 inches between the top
of the drapes and the ceiling.
4. To be suitable for draperies located close to heaters, mate-
rial should not discolour nor distort dimensionally (stretch or
shrink) upon extended exposure (1000 hrs.) to a temperature
of 200º F (93º C).
!
NOTE: If drapes are to be cut off above a heater, they
should be cut off at least 6 inches above the top of the heater
and preferably more.
!
NOTE: Place furniture no closer then 3 inches from the
baseboard heater.

Wall Installation

1. Unpack the heater from the carton and lift the front/top
panel up & off the heater.
2. Remove the desired terminal box covers(s) and supply
wire entry knockouts from the terminal boxes. (See Figure
min
1 for locations)
!
NOTE: It is only necessary to remove the knockout(s) that
will feed the power supply wiring, keeping in mind the heater
mounting location and supply wire location in the wall.
3. Determine the correct mounting height and scribe or snap
a level line on the wall to maintain each heater back plate
in a horizontal alignment, when mounting.
!
NOTE: Bottom air inlet heaters must be mounted a
minimum of 2" from the bottom of the heater to the finished
floor.
4. Mount the back plate to the wall using suitable fasteners
(provided by the customer) using the scribed line on the
wall to keep the heater level.
!
NOTE: Should the wall surface be uneven, secure the
7213140100R02

Advertisement

loading

Summary of Contents for Dimplex SAF6 Series

  • Page 1: Important Instructions

    Architectural Heaters SAF6/SAS8 Series IMPORTANT INSTRUCTIONS Installation Instructions When using electrical appliances, basic precautions should al- WARNING: Wiring procedures and connections should ways be followed to reduce the risk of fire, electric shock, and be in accordance with the National Electric Code (NEC & injury to persons, including the following: CEC) and local codes.
  • Page 2: Wiring Diagrams

    1. Run branch circuit wiring of proper voltage and wire size to the location of the terminal box of the heater. (See above) NOTE: Supply wire entry is commonly made into one heater. Through wiring (factory furnished) can be used for connection to adjacent heaters. www.dimplex.com...
  • Page 3 Manufacturer’s written approval, will sawdust, etc.) from interior and exterior of heater. void this Warranty. Dimplex baseboard heaters are designed and tested for safe This Warranty is in lieu of all other warranties or conditions and trouble-free operation. All Dimplex baseboard heaters whether expressed or implied including but not limited to those are protected against overheating by a built-in thermal cutout.

This manual is also suitable for: