Introduction
This is the Supra TRAC-Lock BT Installation
Instructions. Read these instructions and the lockset
installation instructions before installing TRAC-Lock BT.
If you do not mount the TRAC-Lock BT accurately, it
will not function properly. Supra will not be responsible
for replacing the TRAC-Lock BT if it is damaged or
destroyed upon removal.
Installation supplies provided
Installation instructions
Drill template
Electronics enclosure with lid
Mounting plate (interior)
Exterior TRAC-Lock BT plate
Three 9-volt batteries
Two sets of four #8 flat head screws (Two
different screw lengths for the mounting plate)
Last battery change sticker
One electrified lockset (no lock core)
Four #8 × 5/16 in. (8mm) pan head screws and
lock washers (for electronics enclosure)
Six #4 × 1/2 in. (13mm) flat head screws
Plastic weather cover assembly
CAUTION: The electronics in this package are
electrostatic sensitive devices. Before you install
the unit, discharge or use a grounding belt.
Installation tools required
Drill
Drill bits
File
Phillips screwdriver
Level or punch
Pen or pencil
© 2011 UTC Fire & Security. All rights reserved.
Hardware not provided
When a lockset is provided with the TRAC-Lock BT,
the lockset will not include a lock core. If you install the
TRAC-Lock BT into a door that has a noncylindrical lock
(for example, a mortise lock), you will need additional
hardware. Consult a locksmith for the parts you need for
the conversion.
Figure 1. Standard TRAC-Lock BT installation
Installation notes
The TRAC-Lock BT is designed to be installed above,
below, or to the side of the lockset (Figure 1). We
recommend 6 in. (15 cm) above the lockset, or as far
above the lockset as needed to be out of the way of door
hardware. To meet ADA requirements, the lockset must
be no higher than 48 in. (120 cm) from the ground to
center of the device.
If you install the TRAC-Lock BT in a wood door, align it
horizontally with the lockset and latch (Figure 2). When
drilling, drill the latch set hole through the backset hole
and into the door. You will use this hole to thread the
wiring from the lockset to the TRAC-Lock BT. Align the
TRAC-Lock drill template (PN: 43336) so that the 5/8
in. (16 mm) wire feed hole intersects with the horizontal
hole. Use this channel to feed the wire from the lockset
to the TRAC-Lock BT. When you install the lockset, allow
room for expansion in hot weather.
P/N 10103023P1 Rev B • January 2012

Advertisement

loading

Summary of Contents for Supra TRAC-Lock BT

  • Page 1: Installation Instructions

    48 in. (120 cm) from the ground to center of the device. If you install the TRAC-Lock BT in a wood door, align it horizontally with the lockset and latch (Figure 2). When drilling, drill the latch set hole through the backset hole and into the door.
  • Page 2 Note: The white ferrite snap bead is not required Figure 2. TRAC-Lock BT wood door installation for TRAC-Lock. Installer may discard. Also, Common Wire from Bezel is not required. Installer may remove or leave in bezel. 5. Insert and tighten screws through interior plate. For 1-1/4 to 1-1/2 in.
  • Page 3 2. This device must accept any interference received, including interference that may cause undesired 13. Install the plastic weather cover. operation. 14. Record the TRAC-Lock BT serial number and Changes or modifications not expressly approved by the installation location. party responsible for compliance could void the user’s Battery removal/disposal authority to operate the equipment.