WARNING - Risk of Fire:- Do not operate with flue draft exceeding
Operating at a number above -.07 can cause solid fuel devices to burn back into the hopper.
- Do not store fuel or other combustible material within marked installation clearances.
using ¼-20 bolts with fender washers. Plug convection fan into control module. All plenums installed to the
furnace to be constructed of metal only. .The warm-air supply-duct system to be constructed of materials with a
minimum temperature rating of 250
Install the thermostat in the room you want the temperature to be the most consistent run the supplied
thermostat cable the best route possible factory cable is 25ft optional cables can be purchased 35' 50' 75' and
100'. Or you can use cat 5 Ethernet cable make sure it is straight through configuration. See Coal-Trol user
manual
for
further
www.automationcorrect.com
Specs for AK 110
48" high x 29" wide x 51" deep
Standard hopper capacity 200# optional 320# available
Side flue 6"
Weight assembled 600# empty
Specs for AK 180
48" high x 29" wide x 58" deep
Hopper capacity 320# standard
Side Flue 8"
Weight assembled 800# empty
Specs for AK 220
48" high x 29" wide x 58" deep
Hopper capacity 320# standard
Side Flue 8"
Weight assembled 800# empty
DANGER - Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.
CAUTION - Hot Surfaces: - Keep children away. - Do not touch during operation.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
BURN ANTHRACITE COAL ONLY
- Do on operate with fuel loading or ash removal doors open.
- Inspect and clean flues and chimney regularly.
0
F.
information.
Or
more
Please save these instructions
-.07 in
info
can
be
found
. water column.
at
manufactures
website.