BURN ANTHRACITE COAL ONLY
-.07 in
WARNING - Risk of Fire:- Do not operate with flue draft exceeding
. water column.
Operating at a number above -.07 can cause solid fuel devices to burn back into the hopper.
- Do on operate with fuel loading or ash removal doors open.
- Do not store fuel or other combustible material within marked installation clearances.
- Inspect and clean flues and chimney regularly.
To ensure a safe installation, it is recommended that this furnace be installed by a qualified
installer.
The sheet metal top and sides can be easily removed to reduce the chance of dents or scratches on
the painted surfaces.
To remove the sheet metal, first lift off the top section. Now, the sides can be removed by lifting up and out
away from the furnace
Place the furnace as close to the chimney as possible while still maintaining the proper clearances. No more
than 10 feet of stovepipe should be used, including two or less 90° elbows. All horizontal runs of pipe should
have a minimum 1/4 in. rise per foot. All stove pipe must be 24 gauge or thicker black or blued steel. Do not
use galvanized or Aluminum pipe! A properly sized barometric damper is also needed. 6" pipe for 110kbtu
furnace and 8" pipe for 220kbtu furnace. Type HT (was Class A) / or masonry chimney required for exterior
pipe. If a liner is needed for a masonry chimney use an insulated or fill insulation. Should be made of Stainless
Steel of at least 316 grade. It is a recommended to always check with local code for proper installation.
If no chimney is available a Powervent can be used (SWG5- AF ) for both 110kbtu and 220kbtu purchased
from a Leisure Line Dealer make sure it is labeled for use with a Leisure Line Product. Instructions will be
provided with the Powervent for install.
At least 16 inches (400 mm) in front and 8 inches (200 mm) on either side of the fuel-loading and ash-removal
doors. Furnace is to be installed on non-combustible surface. Underneath the chimney connector and
extending at least 2 inches (50 mm) on either side of the chimney connector. Non-combustible floor must
extend to these dimensions as well.
After selecting the side for the flue, break out the perforated panel at the bottom of the jacket. Install the flue
outlet and outlet blank off plate. Install the bottom jacket filler plate under the flue outlet. Re-install the sheet
metal jacket by sliding the groove on the bottom of each side panel over the steel lip on the furnace. The gap
around the flue outlet can be sealed with fiberglass gasketing such a rope or thick flat gasket. The top sheet
metal piece holds the sides in place. Making sure the jacket insulation is properly in place.
Next install the feeder in the back of the unit, the grate(s) can be removed to make this process easier. Using
the 4 bolts supplied, tighten just past snug about 80in/lbs. Next install the hopper placing the gasket(s) around
hopper opening(s) of the feeder first. Use the ¼-20 bolts with the angle support.
Mount fan extension box to fan using ¼-20 bolts and nuts supplied . If you are installing the cold air return box
assemble to the fan assembly now. Filter is removable by sliding it to the front or rear after removing holding
tab, Select what side of the hopper you want the thermostat module mount it to the bottom of the hopper using
supplied self drilling screws (The holes can be predrilled to make it easier. ) keeping it about 1.5"- 2 " from
back of furnace. Try to keep metal shavings from falling into module box. Feeder motor(s) and combustion
blower(s) can be wired at this time using blue wire nuts supplied. Red wires are for feeder gear motor, Blue
wires are for the combustion blowers. If you are wiring a 220kbtu the red w/white trace and blue w/white trace
nd
are for 2
feeder Route the conduit neatly and out of the way. Next install the convection fan to the furnace
DANGER - Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.
CAUTION - Hot Surfaces: - Keep children away. - Do not touch during operation.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
Please save these instructions