LG DLEX5101W Service Manual page 13

Electric & gas dryer
Hide thumbs Also See for DLEX5101W:
Table of Contents

Advertisement

5
Component
7. Heater
8. Thermistor
9. Motor
10. Gas valve
valve 1
valve 2
11. Igniter
5318EL3001
MEQ61841001
12. Frame Detect
Test Procedure
Measure resistance of the
following terminal
Terminal: 1 (COM) - 2
Terminal: 1 (COM) - 3
Terminal: 2 - 3
Measure resistance of terminal
to terminal
Temperature condition:
58°F ~ 104°F (10~40°C)
Measure resistance of the
following terminal
Valve 1 terminal
Valve 2 terminal
Measure resistance from
terminal to terminal.
Measure resistance of termina
to terminal
Open at 370°F (Maximum)
Close at 320°F
Check result
Resistance value: 10Ω
Resistance value: 10Ω
Resistance value: 20Ω
Resistance value: 10Ω
Resistance value 2.3k~2.7kΩ
Resistance value 2.3k~2.7kΩ
Resistance value
50~800 Ω
(for 5318EL3001)
40-150 Ω
(for MEQ1841001)
Resistance value
Resistance value < 1Ω
12
Remark
• Electric type
• Heater case
Hi limit
• Electric type
• See Page 14
• Gas type
• Gas type
• Gas type

Hide quick links:

Advertisement

Table of Contents
loading