Electrical defects

In case of a breakdown of heating or sensor, the electric of the HP07 has to be exchanged. The
procedure is as follows;
Release pressure of the system
Disconnect the electrical connection of hose and HP07
Disconnect the hydraulic connection of hose and HP07
Loosen all hexagon socket screws and remove HP07 housing
Disconnect electric and cord set (Pos.6)
Remove the entire service block with trigger and electric out of the housing (Pos.1, 3, 4)
The safety lever has to be put into secured position so that the cable channel is laid open and the
service block with trigger and electric can be taken out of the housing.