H Y U N D A I W AT E R
ANAlOG HOT ANd COld wATER PURIfIER CONTROlS
After installing the
and connecting power and water supply, turn on the red switch
POU
in the back of the machine. The cold water "set as default" can be adjusted by turning the
green dial labeled
.
COld
After the tanks are full and the hot and cold temperatures reached, the water is ready for
consumption.
mAINTENANCE & INSTAllATION TIPS:
Pre-flush filters prior to allowing water to migrate to the storage tanks.
Allow each system to process water to full capacity at least 2 times and completely flush
system before moving to customer location.
Carefully inspect all filters and tubing connections for leaks prior to final installation.
When transporting to installation location, be sure to do so, using all packaging unit was
shipped with.
NEVER lay unit down on its side, it is recommended not to tilt unit more than 15 degrees
prior to installation. If unit is tilted more than 15 degrees, unit should stand in vertical
position for 24 hours prior to installation.
Connect directly to electrical outlet; DO NOT use an extension cord!
After unit is properly connected to water and power, it is advisable to remain with unit for
approximately 30 minutes to observe start-up. Fittings can become loose or stressed dur-
ing transportation. Be sure to give a final check of all connections prior to walking away
from your installation for best results.
Reverse-Osmosis units produce water at a reduced and varying rate of production as com-
pared to micro or ultra filtration systems.
Time to fully satisfy the storage capacity of these systems will depend on the unit you are
installing, water pressure and the quality of the water you are purifying.
2 0
hyundai manual_8.indd 24-25
W AT E R P U R I F E R S Y S T E M
H Y U N D A I W AT E R
fAQ
1) THE wATER IS NOT COld ENOUGH.
Have you used too much cold water recently?
Your purifier has a specific cold and/or additional reservoir capacity so please wait a
sufficient period of time before reuse.
Have you checked the voltage of your Purifier?
Your Purifier operates at 110 V. Please do not operate at any other voltage.
Is the back panel of the purifier too close to the wall?
Certain components of your purifier cause heat and the POU should not be too close
to the wall or other structure.
Is the Purifier in direct sunlight or near a heat source?
Please move your product to another location away from the heat source.
Is the temperature of the water supply appropriate?
The water feed temperature should be less then 86°F (30°C).
2) THE wATER IS NOT HOT ENOUGH.
Have you used too much hot water recently?
Please wait a sufficient period of time before re-use.
Is the hot water switch set to 'off '?
The hot water switch is located on the back panel of the purifier; please ensure it is
set to 'on'.
Is the water supply adequate?
Insufficient supply of water could be the reason – ensure the tank is filled with water.
3) THE wATER PURIfIER IS NOT fUNCTIONING PROPERly.
Is this a power failure?
Please check the power supply with other electrical appliances. Also check if the fuse
is disconnected or burnt. Please consult with an electrician for replacement.
Is the purifier emitting an irregular sound?
Please ensure the area of installation is flat and solid.
The purifiers may emit a vibration upon a first install and this is completely
normal as the auto-shut-off valve is under pressure. After the initial install and flush