Easy CON Media Converter User Manual (Translation of Original docu) Document Version 1.2 GOEPEL electronic GmbH Goeschwitzer Str. 58/60 •D-07745 Jena + 49-3641-6896-597 • ats_support@goepel.com • www.goepel.com...
Page 2
The hardware and software might be modified also without prior notice due to technical progress. In case of inaccuracies or errors appearing in this manual, GOEPEL electronic GmbH assumes no liability or responsibility. Without the prior written permission of GOEPEL electronic GmbH, no part of this documentation may be transmitted, reproduced or stored in a retrieval system in any form or by any means as well as translated into other languages (except as permitted by the license).
CAT6) for the test-setup. For easy connection to the ECU cabling harness, an adapter cable with 9-Pol. D-Sub connector is included. The Easy CON Media Converter can be operated as BroadR-Reach Master or Slave. Selection is easily done via a switch on the device`s rear plate (not visible in the following figure).
Use of the Device Use of the Device Specifications and Connections 2.1.1 Technical Easy CON Media Converter Data Baud rate: 10 MBit/s, 100 MBit/s (full duplex) ♦ Forward Delay BroadR Reach to 100Tx: 940 ns ♦ Forward Delay 100Tx to BroadR Reach: 280 ns ♦...
2.2.2 Node 2 Physical layer: BroadR-Reach one pair Ethernet Connector type: R45 socket with Status LEDs BroadR-Reach TRx+ TRx- not connected not connected not connected not connected not connected not connected Easy CON Media Converter...
Pin-out D-Sub Adapter cable D-Sub (plug) RJ45 BroadR-Reach BroadR-Reach not connected TRx+ not connected TRx- Shield not connected TRx+ not connected TRx- not connected not connected not connected not connected not connected not connected not connected not connected Easy CON Media Converter...
Use of the Device 2.2.3 Status Easy CON provides some information regarding the device operating status and the status of the two links. LEDs The individual Status LED at the front side indicates the following states: YELLOW constant on: Device initialization (after RESET) ♦...
Connect your Easy CON device via the supplied USB cable with the supplied Wall Power Supply Set the Sliding switch at the Easy CON to Master or Slave according to the application Plug in the Network cable and BroadR-Reach Adaptor...
Accessories Accessories As accessory for Easy CON the following devices are delivered: 1 Wall Power Supply (Figure 2-1) ♦ 1 Adapter cable RJ45 to D-Sub 9-poles ♦ Easy CON Media Converter...
Page 15
Accessories ....... 3-1 First steps ......2-6 Adapter cable ....2-4 Interfaces ......2-3 Concept of the device ..1-1 Conections ......2-2 LEDs ......... 2-5 Easy CON Technical data ....2-1 Wall power supply ..... 3-1 Easy CON Media Converter...
Need help?
Do you have a question about the Easy CON and is the answer not in the manual?