Page 1
Instructions for use and warranty details Domino Gas Model No.: DG and DGW www.fulgor.com.au...
Page 3
Once installation is complete, please read this entire instruction manual carefully and get to know the controls and the features of your new Fulgor Milano appliance. Again, congratulations and thank you for choosing...
Dear customer, We thank you and congratulate you on your choice. This new carefully designed product, manufactured with the highest quality materials, has been carefully tested to satisfy all your cooking demands. We would therefore request you to read and follow these easy instructions which will allow you to obtain excellent results right from the start.
Instructions for use Installation Programming the burner switch-off time It is possible to independently programme each burner All the operations concerned with the installation to switch off automatically after a specific length of time. (electrical and gas connections, adaptation to type of To programme the timer of a burner, press the PT key.
Page 6
The flashing digit to the left of the dot indicates the hours, Special slow cooking (Duty cycle) while those to the right indicate the minutes. It is possible This function turns any cook top burner on and off is the to increase or decrease the hours using keys +A or -A sequence shown in the table.
Page 7
Mod: DG DECIMAL POINTS PUNTI DECIMALI DISPLAY "A" DISPLAY "B" LED "B" LED "A" DISPLAY TIMER PT KL -A +A -B +B Fig. 1 Mod: DGW DECIMAL POINTS PUNTI DECIMALI DISPLAY "A" DISPLAY "B" LED "B" LED "A" DISPLAY TIMER...
Instructions for the installer Installation Positioning (Fig . 5) Overhead clearances - (Measurement A) Side clearances - (Measurement B, & C) Must be installed by an authorized preson in accordance with AS5601 (gas installations), local authority and any other statutory regulations. Fig.
Gas c onnection (Fig. 8) Electrical connection (Fig. 9) The connection to a gas tank or gas line must be made The installer must be qualified and is responsible for by a qualified person in conformity to current updated correct electrical connections and following safety UNI-CIG 7129 and 7131 standards after making standards.
Page 12
Adaptation to varius types of gas (Fig. 10) will show the indication - if the minimum level programmed corresponds with the factory setting, and the indication will change ^ or v in flashing mode, indicating a higher or lower Should the appliance be pre-set for a different type of capacity than that programmed.
Page 13
Error Problem type Possible cause Possible solution displayed Restore the gas and unlock the No gas burners Clean or reposition the Single burner locked Ionization elect rode dirty or not hit by the flame electrode and unlock the burners Check the cables and unlock The cook top is not grounded the burners Parasite flame/flame detection...
Page 14
Total gas consumption for Model GE12-10 on Natural gas 44.2 MJ/h and propane LPG 43.8 MJ/h Total gas consumption for Model DG on Natural gas 37.6 MJ/h and propane LPG 37.1 MJ/h Total gas consumption for Model GE7-10 on Natural gas 16.0 MJ/h and propane LPG 16.0 MJ/h...
Page 15
Upon receipt of a valid Claim, a Local Servicing Agent will attend your premises to inspectthe Product. Where a Product is found to be defective, Fulgor Milano Australasia will, at its option and expense, repair or replace the Product or the defective material or part. If Fulgor Milano Australasia repairs or replaces a defective Product, the warranty period for any Product repaired or replaced does not extend beyond the original Warranty Period.
Page 16
If You are unable to provide Proof of Purchase, Fulgor Milano Australasia will not be obliged to repair or replace the defective Product. Fulgor Milano Australasia will not be responsible for any costs or expenses, loss or damage, associated with: Any transport of the Product to a Local Servicing Agent;...
Need help?
Do you have a question about the DG and is the answer not in the manual?
Questions and answers