Page 1
Instructions for use and warranty details Gas Cooktop Model No.: G6-10 and G9-10 www.fulgor.com.au...
Page 3
Once installation is complete, please read this entire instruction manual carefully and get to know the controls and the features of your new Fulgor Milano appliance. Again, congratulations and thank you for choosing...
Dear Customer, we would like to thank you and congratulate you on your choice. This new product has been carefully designed and built using top quality materials, and meticulously tested to ensure that it meets all your culinary requirements. Please read and observe these simple instructions, which will enable you to achieve excellent results from the very first time you use it.
EN 30-1-1. AS/NZS 3350-1, 3350-2-6 Fulgor Milano, would invalidate any warranty or As Fulgor Milano have a policy of continued product liability claim. Your new appliance is guaranteed improvement, the right is reserved to adjust and...
Do Not Modify This Appliance This appliance complies with all current European Fulgor Milano declines any responsibility for injury safety legislation, however Fulgor Milano do wish to or damage to persons or property as a result of emphasise that compliance does not remove the improper use or installation of this appliance.
The following models are covered by these Ø 20-32 fast instructions: Ø 20-26 semi fast Ø 14-20 auxiliary* G6-10 – 4 burner (including wok), stainless steel Ø 10-14 hob, standard enamel or optional cast iron trivets * with reduction grid with flame failure & auto ignition G9-10 –...
Installations and any other statutory regulations. of the hole cut in the worktop. • Gas safety regulations (Installation & Use) • Fulgor Milano Installation Instructions. Installation notes 1. Cut the aperture to the dimensions shown below or use the template if printed on the packaging.
Model T.P.P. (kPa) Burners Natural Gas Propane (LPG) G6-10 2.75 Wok+ Rapid G9-10 2.75 Wok+ Rapid Gas connection When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced with Data Label – The Data Label is located on the the Test Point Assembly.
Gas flow adjustment Adaptation to various types of gas (Fig. 7) In order to adjust the minimum gas flow proceed as follows: Should the appliance be pre-set for a different type of gas than available, proceed as follows: • Ignite the burner and turn down to the minimum setting.
User characteristics Electrical connection The electrical outlet is to be positioned in an easily accessible position adjacent to the appliance. Before connecting the appliance, make sure In the event that it is necessary to replace the mains the supply voltage marked on the rating Plate supply lead, the replacement must conform to the corresponds with the mains supply voltage.
Page 12
Should there be no cable and/or plug on the , t n a t i o i t l a i for the working temperature as well, as indicated on the matrix plate. Under no circumstance must the cable reach a temperature above 50°C of the ambient temperature.
Maintenance Technical data WARNING: SERVICING SHOULD BE CARRIED Electrical details OUT ONLY BY AUTHORISED PERSONNEL Rated Voltage 230V ac 50Hz During the warranty period, in case of need all Supply Connection 1OAmp GPO service intervention should be referred back to the Power Input 0.008 to 0.02kW (depending on model) Kleenmaid Service Department.
Page 14
Natural gas burner types and power outputs: mj/h Semi Rapid Total Mj/h Model Wok Max Rapid Max Auxiliary Max G6-10 G9-10 Propane gas burner types and power outputs: mj/h Semi Rapid Total Mj/h Model Wok Max Rapid Max Auxiliary Max...
Upon receipt of a valid Claim, a Local Servicing Agent will attend your premises to inspectthe Product. Where a Product is found to be defective, Fulgor Milano Australasia will, at its option and expense, repair or replace the Product or the defective material or part. If Fulgor Milano Australasia repairs or replaces a defective Product, the warranty period for any Product repaired or replaced does not extend beyond the original Warranty Period.
Page 16
If You are unable to provide Proof of Purchase, Fulgor Milano Australasia will not be obliged to repair or replace the defective Product. Fulgor Milano Australasia will not be responsible for any costs or expenses, loss or damage, associated with: Any transport of the Product to a Local Servicing Agent;...
Need help?
Do you have a question about the G6-10 and is the answer not in the manual?
Questions and answers